Instruction Manual for AirExchange Elements 12-R Monoblock Air Conditioner

Quick guide for the AirExchange Elements 12-R monoblock air conditioner, covering installation, operation, Wi-Fi setup, maintenance, and troubleshooting.

Table of contents

Quick guide from the manual

This document provides essential instructions for the installation, operation, and maintenance of the AirExchange Elements 12-R monoblock air conditioner. The system uses R290 refrigerant and must be installed on an exterior wall. Ensure at least 20cm of clearance above the unit for proper airflow. The system is a closed unit and does not provide fresh outdoor air ventilation.

Device description

The unit features a touch-control panel, a carbon filter with a PTC heating element, and an internal heat pump. It includes a remote control and wall mounting accessories.

Installation

Installation must be performed on a solid vertical wall. Steps:

  • Determine the position and mark the wall using the provided template.
  • Drill ventilation holes (2x) and the water outlet hole (1x) with a 2-3 degree downward angle.
  • Install the mounting bracket using the provided plugs and screws.
  • Fold the plastic sheets to a round shape and insert them into the ventilation holes.
  • Mount the unit onto the bracket and guide the water drainage pipe through the 25mm hole.
  • Secure the bottom bracket and ensure the unit is firmly pressed against the wall using the provided sealing strip.

Operation and settings

The unit offers cooling, heating, recirculation, and dehumidification modes. The display shows the current temperature, Wi-Fi status, and active modes. The 1000W heating booster is available when the room temperature is below 18°C and the set temperature is at least 5°C higher.

Wi-Fi connectivity

To connect to Wi-Fi, download the Smart Life app. Press the wind speed button on the display for 5 seconds until the Wi-Fi icon flashes, then follow the app instructions to add the device.

Maintenance

Replace the filter set at least once a year. When cleaning, use a dry, anti-static microfiber cloth. Do not use paper towels or old clothes to avoid scratching the surface. Wear protective gear (mask, gloves, goggles) when replacing the filter.

Troubleshooting

If the system does not turn on, check the power supply and ensure air inlets are not blocked. If the unit leaks water, verify the drainage pipe is correctly installed and not clogged. For abnormal noises, check if the unit is level and firmly mounted.

Contact

For support, contact AirExchange at [email protected] or call +31(0)182-235055.

Manufacturer information

AirExchange

Brand profile

Practical help

Common problems

System does not turn on or no air output

Check power supply, ensure air inlets/outlets are not blocked, and verify temperature settings.

System leaks water

Check if the drainage pipe is installed correctly, not clogged, and led outside.

Remote control not working

Replace batteries (2x AAA) and clean the sensor on the unit.

Humming or strange noises

Ensure the unit is level, the mounting bracket is secure, and the foam layer is pressed flat against the wall.

Before use

  • Ensure the unit is installed on an exterior wall.
  • Verify at least 20cm of space above the unit.
  • Check that the drainage pipe is correctly positioned.
  • Ensure the wall is flat and the sealing foam is compressed.
  • Check that the power supply is 220-240V/50Hz.

Specs in practice

Cooling capacity
12,000 BTU/h, suitable for rooms up to 80m².
Heating efficiency (SCOP)
3.6, indicating high energy efficiency during heating.

Model compatibility

  • Wi-Fi requires a 2.4GHz network.
  • Not suitable for rooms smaller than 15m².