The Delta IB Series power entry modules are integrated units combining an IEC connector, a fuse holder (single or double), and a double-pole power switch with an EMI filter. These modules are designed for easy installation in industrial and electrical applications. All models are UL recognized, CSA certified, and VDE approved.

Specifications

  • Rated Voltage: 115/250VAC
  • Operating Frequency: 50/60Hz
  • Maximum Inrush Current: 50A
  • Switch Electrical Lifetime: 10,000 cycles
  • Maximum Leakage Current: 0.2mA at 115VAC/60Hz; 0.4mA at 250VAC/50Hz
  • Hipot Rating (1 minute): 2250VDC (line-to-ground); 1450VDC (line-to-line)

Mechanical Construction and Mounting

The modules are designed for panel mounting. When preparing the installation, refer to the suggested mounting cutout dimensions provided in the technical drawing. The unit requires a cutout of 60.0mm x 40.0mm (2.360" x 1.575"). Ensure the panel thickness and clearance allow for the module depth of 56.0mm to 66.0mm depending on the specific configuration.

Electrical Schematics

The series utilizes two primary schematic configurations:

  • FIG. A: Used for models with double-fuse holders (e.g., 01IB2D, 03IB2D, 06IB2D).
  • FIG. B: Used for models with single-fuse holders (e.g., 01IB2S, 03IB2S, 06IB2S).

Practical help

Common problems

Exceeding current ratings

Ensure the load does not exceed the rated current (1A, 3A, or 6A) specified for your specific part number at the operating voltage.

Incorrect fuse configuration

Verify if your model (D-suffix or S-suffix) requires a single or double fuse setup as per the electrical schematic.

Before use

  • Verify the part number matches your required current rating (1A, 3A, or 6A).
  • Check if the application requires a single or double fuse holder.
  • Ensure the panel cutout dimensions match the 60.0mm x 40.0mm specification.
  • Confirm the operating voltage is within the 115/250VAC range.