GARO RCBO 10kA Residual Current Breaker with Overcurrent Protection

Quick guide for the GARO RCBO 10kA residual current breaker. Includes technical specifications, wiring diagrams, and installation dimensions for models RCBOLIB...R and RCBOLIC...R.

Table of contents

Manual images

Click an image to enlarge

Quick Guide

This document provides the technical specifications and installation parameters for the GARO RCBO 10kA series (RCBOLIB...R, RCBOLIC...R). This device is a residual current breaker with overcurrent protection, designed for electrical installations. Ensure all work is performed by a qualified electrician in accordance with local regulations.

GARO RCBO 10kA device
GARO RCBO 10kA device

Technical Specifications

The following technical data applies to the GARO RCBO 10kA series:

  • Rated voltage (Un): 230V AC
  • Rated current (In): 6 - 45A
  • Minimum supply voltage (Umin): 230V
  • Rated frequency (fn): 50 Hz
  • Rated short-circuit capacity: 6 kA
  • Back-up fuse: 100A gG
  • Tripping characteristic: B, C
  • Type: A
  • Rated residual current (IΔn): 30, 100 mA
  • Rated residual making & breaking capacity (IΔm): 6000A
  • Terminals: 1-25mm², max. 3Nm
  • Width: 18 mm
  • Standards: IEC 61009

Wiring and Dimensions

The device features a standard 18mm module width. The wiring diagram (KZ9-1M FN) indicates the connection points for Line (L) and Neutral (N) inputs and outputs. Ensure that the wire cross-section used is within the 1-25mm² range and that terminal screws are tightened to a maximum of 3Nm.

Additional installation photo from page 2
Additional installation photo from page 2

Manufacturer information

Garo AB

Brand profile

Practical help

Common problems

Device fails to trip or trips unexpectedly

Verify that the rated residual current (30mA or 100mA) matches the circuit requirements and check for leakage or short-circuit faults in the downstream installation.

Terminal connection issues

Ensure wire size is between 1-25mm² and torque is applied correctly (max 3Nm) to prevent loose connections or damage.

Before use

  • Verify that the supply voltage is 230V AC.
  • Ensure the rated current (6-45A) is appropriate for the circuit load.
  • Confirm the residual current sensitivity (30mA or 100mA) is correct for the application.
  • Check that the wire size is within the 1-25mm² range.
  • Ensure the installation environment complies with IEC 61009 standards.