User Manual for Solight 1T04A Breath Analyzer
Quick guide for the Solight 1T04A breath analyzer. Learn how to perform measurements, set units, manage memory, and maintain your device for accurate results.
Quick answers from the manual
Quick answer
- To use the Solight 1T04A, turn it on, wait for the 'READY' signal after the countdown, and blow into the mouthpiece for 5-6 seconds until the double beep. p. 1
Key actions
- Perform a measurement p. 1
- Change units and alert levels p. 2
First start
- Insert 3x AAA 1.5V alkaline batteries, turn on the device, and wait for the 1-minute sensor warm-up. p. 1
Problems and fixes
Blowing was not detected during the 'READY' mode.
p. 1Maintenance and reset
- Clear memory by removing batteries for 5 seconds. p. 2
Technical specifications
| Parameter | Value | Meaning | Pages |
|---|---|---|---|
| Measurement range | 0.000 - 3.000 ‰ | Range of alcohol detection | p. 3 |
| Accuracy | ± 0.1 ‰ | Measurement tolerance after calibration | p. 3 |
Where to find it in the PDF
- Instructions and Operation p. 1
- Memory and Settings p. 2
- Technical Data and Maintenance p. 3
Table of contents
Manual images
Click an image to enlargeQuick Guide
The Solight 1T04A is a digital breath analyzer designed to measure alcohol content in breath. To perform a test, ensure the device is powered on, wait for the sensor warm-up (indicated by the countdown), and blow into the mouthpiece when the 'BLOW' icon appears. Always rinse your mouth with water and wait at least 10 minutes after consuming alcohol before testing to ensure accuracy.
Device Description
The device features a digital display, a swivel mouthpiece, a power button, and a memory button. The display provides status updates including 'WAIT', 'READY', 'BLOW', and 'READING'. It also shows battery status and measurement results.

Power Supply
The device operates on 3x AAA LR03 1.5V alkaline batteries. 1.2V rechargeable batteries are not recommended as they may cause low battery warnings and reduced display intensity. Alternatively, the device can be powered directly via a 5V USB power adapter; note that the USB cable does not charge the batteries.
Measurement Procedure

- Rinse your mouth with clean water. Do not smoke or drink alcohol for at least 10 minutes prior to testing.
- Attach the swivel mouthpiece. If testing multiple people, use a new mouthpiece tube for each person.
- Press the power button for 1 second to turn on the device.
- Wait for the sensor to warm up (approx. 40 seconds). The display will count down to zero, show 'READY', and then flash 'BLOW'.
- Insert the mouthpiece and blow continuously for 5 to 6 seconds.
- Stop blowing after the double beep. The device will analyze the sample, flashing 'READING'.
- The result will be displayed. If the value is below 0.200 ‰, it will show 0.000 ‰ or 0.100 ‰.
Memory and Settings
The device stores the last 20 results. Press the Memory button to view them. To clear memory, remove the batteries for 5 seconds. To change units (‰ BAC, % BAC, mg/L) or alert levels (0.1 to 1.0), remove the batteries, then press and hold the power button while reinserting them. Use the power button to cycle units and the memory button to adjust alert levels. Hold the memory button for 2 seconds to save.
Maintenance and Storage
- Clean the test chamber by shaking the instrument or using a stream of fresh air (e.g., a fan) to remove residue from previous tests.
- Store in a dry environment free of chlorine or corrosive gases.
- Do not drop the device or expose it to shock.
- Recalibrate every 12 months or replace the sensor module.
- Use a dry cloth for cleaning; do not use abrasives or solvents.
Technical Data
- Measurement range: 0.000 - 3.000 ‰
- Measurement accuracy: ± 0.1 ‰ after calibration
- Operating temperature: +5 °C to +45 °C
- Automatic shutdown: Approximately 60 seconds after last use
Practical help
Common problems
Rinse mouth with water, wait 10 minutes after alcohol consumption, and ensure the test chamber is clean.
Blowing was not detected during the 'READY' mode. Ensure you blow continuously for 5-6 seconds.
Replace batteries immediately. 1.2V rechargeable batteries may cause false low battery warnings.
Before use
- Rinse mouth with clean water.
- Wait at least 10 minutes after consuming alcohol or smoking.
- Ensure 3x AAA 1.5V alkaline batteries are installed correctly.
- Attach the swivel mouthpiece.
- Ensure the air outlet is not blocked during blowing.
Specs in practice
- Measurement range
- 0.000 - 3.000 ‰
- Operating temperature
- +5 °C to +45 °C
- Auto-shutdown
- Device turns off automatically after 60 seconds of inactivity.
Images and diagrams
- The display shows 'WAIT' during the 40-second sensor warm-up.
- The 'BLOW' icon indicates the device is ready for the breath sample.
- The 'READING' text flashes while the device analyzes the sample.
Model compatibility
- Use only 1.5V alkaline batteries (3x AAA LR03).
- 1.2V rechargeable batteries are insufficient for proper operation.
Manual page author
Emily Carter
User documentation editor
Prepares concise manual descriptions and highlights the most useful setup, operation, and maintenance information for readers.