Stoves 110CM Chimney Cooker Hood Installation Manual
Installation guide for the Stoves 110CM chimney cooker hood, covering mounting, ducting, and configuration for extraction or recirculation modes.
Table of contents
Product Overview
The Stoves 110CM chimney cooker hood is designed for kitchen ventilation. This document provides essential installation instructions for both extraction and recirculation modes. Before beginning the installation, ensure you have read the safety information provided in the main user manual.
Safety and Preparation
Installation must be performed by qualified personnel. Always wear protective gloves during the installation process to prevent injury from sharp edges. Ensure the mounting surface is stable and capable of supporting the weight of the hood.
Installation Requirements
The hood must be installed at a minimum distance of 500mm above electric hobs and 650mm above gas hobs. The unit is compatible with 120mm or 150mm diameter ducting for extraction mode. For recirculation mode, ensure the appropriate charcoal filters are installed.
Installation Steps
The installation process involves marking the wall, drilling holes, and securing the mounting brackets. The chimney sections (N1 and N2) are adjustable to accommodate different ceiling heights. Ensure the unit is perfectly level before final tightening of the screws. For extraction mode, connect the ducting to the outlet and secure it with clamps. For recirculation mode, install the air diverter (O2) and the charcoal filter (W).
Maintenance
Regular maintenance is required to ensure optimal performance. The grease filter (Z) should be cleaned periodically. If using the hood in recirculation mode, the charcoal filter (W) must be replaced according to the manufacturer's schedule to maintain air quality.
Manufacturer information
Stoves
Practical help
Common problems
Use a spirit level during the mounting phase and adjust the bracket screws before final tightening.
The unit supports 120mm or 150mm diameter ducting; ensure the correct adapter is used for your specific setup.
Before use
- Verify the wall can support the weight of the hood.
- Ensure the minimum clearance of 500mm (electric) or 650mm (gas) is maintained.
- Wear protective gloves during installation.
- Check that all mounting hardware (screws, wall plugs) is included.
- Determine if the hood will operate in extraction or recirculation mode.
Specs in practice
- Minimum Height (Electric)
- 500mm clearance required above electric hobs.
- Minimum Height (Gas)
- 650mm clearance required above gas hobs.
- Ducting Diameter
- Supports 120mm or 150mm diameter pipes for extraction.
Model compatibility
- Requires specific charcoal filters for recirculation mode.
- Ducting diameter must be matched to the chosen outlet adapter (120mm or 150mm).
Manual page author
Emily Carter
User documentation editor
Prepares concise manual descriptions and highlights the most useful setup, operation, and maintenance information for readers.