Bosch Professional GFP 18V-10 Cordless Grease Gun User Guide
Quick start guide for the Bosch Professional GFP 18V-10 cordless grease gun, covering assembly, cartridge installation, operation, and maintenance.
Table of contents
Quick guide from the manual
The Bosch Professional GFP 18V-10 is a cordless grease gun designed for lubricating moving parts via standard lubrication points. It supports 400g pull-off cartridges, 500g screw-in cartridges, and 400g screw-in cartridges. The tool features adjustable pump stroke preselection and two gear settings to regulate grease flow and pressure.
Assembly and Setup
- Shoulder strap: Hook the strap into the brackets (15).
- Hose replacement: Use a wrench to loosen the nut (21) and replace the hose (19). Tighten to 13–16 Nm.
- Cartridge installation: Unscrew the grease cylinder (12), pull the spring rod (23) out, and lock it. Insert the cartridge, remove the seal, and reattach the cylinder.
- Bleeding: Always bleed the system after changing cartridges or filling the cylinder to ensure continuous grease flow. Use the bleed valve (14) until grease escapes continuously.
Operation
- Pump stroke preselection: Use the thumbwheel (2) to set a specific number of strokes (1–50) or set to 'ON' for continuous operation.
- Gear selection: Use the switch (7) to select between Gear 1 (100 g/min, max 10,000 psi) and Gear 2 (320 g/min, 6,000–8,000 psi).
- Switching on/off: Unlock the switch using the locking mechanism (4), then press and hold the on/off switch (6). Use the lock-on button (5) for continuous operation.
Maintenance and Safety
- Pressure relief valve: If pressure exceeds 10,000 psi, the valve (18) opens and the tool shuts off automatically. Check for blockages in the hose or lubrication point.
- Cleaning: Keep the tool and ventilation slots clean.
- Battery: Remove the battery before any maintenance or cartridge changes.
Manufacturer information
Bosch
Practical help
Common problems
The pressure relief valve (18) has opened due to excessive pressure (>10,000 psi). Check the lubrication point and hose for blockages.
The system may need bleeding. Use the bleed valve (14) to remove air from the cylinder.
Ensure the hose is tightened to a torque of 13–16 Nm.
Before use
- Check the grease gun and hose for any damage or wear.
- Ensure the hose is not blocked or kinked.
- Verify the battery is charged and inserted correctly.
- Ensure the correct adapter is used for the specific cartridge type.
- Bleed the system after installing a new cartridge.
Specs in practice
- Max. operating pressure
- 10,000 psi; exceeding this triggers the pressure relief valve.
Model compatibility
- Compatible with 400g pull-off cartridges.
- Compatible with 500g screw-in cartridges using adapter (28).
- Compatible with 400g screw-in cartridges using adapter (29).
Manual page author