This document provides operating instructions for the Güde GAB 12V/6V-10A (85142) and GAB 12V-15A (85143) automatic battery chargers. These devices are designed for charging and starting vehicles. Always read the full safety instructions before use.

Safety instructions

  • The device is intended for use by persons aged 16 or older.
  • Children aged 8 and above may use the device under supervision or if instructed on safe use.
  • Do not use the charger in moist or wet conditions; for indoor use only.
  • Ensure cooling slots are not covered.
  • Do not operate near heat sources or on flammable surfaces.
  • Always disconnect from the mains before connecting or disconnecting battery cables.
  • Battery charging produces explosive gases; avoid fire, sparks, and smoking.
  • Wear protective goggles and gloves.

Charging procedure

  1. Connect the red battery clip to the positive (+) terminal.
  2. Connect the black battery clip to the negative (-) terminal (if mounted in the vehicle, connect to the chassis, away from the battery and fuel line).
  3. Plug the charger into a mains socket.
  4. After charging, disconnect the charger from the mains.
  5. Remove the black clip from the chassis/negative terminal, then the red clip from the positive terminal.

Charging steps and error codes

The charger automatically adapts the charging line through six steps: Diagnosis, Soft Start, Bulk, Absorption, Analysis, and Maintenance. If an error occurs, the display will show an error code:

  • E01: Charger temperature too high.
  • E02: No-load or battery voltage too low.
  • E03: 6V mode selected for 12V battery.
  • E04: Battery cannot hold charge (defective).
  • E05: Battery did not reach threshold (defective).
  • E06: Reverse connection.
  • P12: Cigarette lighter active.

Maintenance and disposal

Keep connection clamps and the battery surface clean. Clean only with a dry cloth. Do not dispose of the device or batteries with household waste; use designated recycling collection points.

Service

For technical questions, spare parts, or complaints, visit the service section at www.guede.com. Contact: Tel. +49 (0) 79 04 / 700-360, Fax +49 (0) 79 04 / 700-51999, E-Mail [email protected].

Practical help

Common problems

Charger displays E06

Reverse connection detected. Check that the red clip is on the positive (+) terminal and the black clip is on the negative (-) terminal.

Charger displays E03

6V charging mode is selected for a 12V battery. Change the mode.

Charger displays E04 or E05

The battery is likely defective and cannot hold a charge or reach the required threshold.

Before use

  • Ensure the device is not damaged (cables, plug).
  • Ensure the vehicle is switched off and the ignition is off.
  • Ensure the area is well-ventilated.
  • Wear protective goggles and gloves.
  • Check that the battery type is compatible (Lead-acid, Gel, AGM, WET, MF).

Specs in practice

Rated capacity
The range of battery sizes (Ah) the charger can handle.
Safety class II
Double-insulated device, does not require a grounded plug.
Charging rms current
The current output levels available for charging.

Model compatibility

  • Not suitable for Li-ion, NiCd, or NiMH batteries.
  • Only for charging and starting vehicles.
  • Suitable for indoor use only.