This document provides essential instructions for the DeWalt DXPW 001M and DXPW 002M high-pressure washers. It covers assembly, safe operation, maintenance, and troubleshooting. Always ensure the machine is placed on a firm, stable surface during operation and is properly supplied with water to prevent damage.

Assembly

The appliance is delivered partially assembled. Refer to the illustrations in the manual (Fig. 2) for the assembly sequence. Ensure the appliance is disconnected from the power supply before performing any assembly or installation.

Startup and Operation

  1. Turn on the water supply tap fully.
  2. Release the safety catch (D).
  3. Depress the gun trigger for a few seconds to vent air, then start the appliance using the starter device (ON/I).

Note: If the gun trigger is released, the dynamic pressure automatically cuts out the motor. When depressed, the pressure drop restarts the motor. Allow 4-5 seconds between releasing and depressing the trigger for correct operation.

Maintenance

Always disconnect the plug from the power socket before performing any maintenance. Inspect the power cable, high-pressure hose, fittings, trigger gun, and lance before each use. Clean the nozzle using the provided tool (C1) and inspect the inlet filter (L) regularly.

Storage and Transportation

Before winter storage, run the machine with non-aggressive, non-toxic antifreeze. Store the machine in a dry place, protected from frost. Transport the machine as illustrated in the manual.

Safety Warnings

  • Do not point the water jet at people, animals, or electrical equipment.
  • Do not use the appliance if the electric cable or high-pressure hose is damaged.
  • Do not allow children or untrained persons to use the appliance.
  • Wear appropriate protective clothing (PPE) during operation.
  • Ensure a minimum distance of 15 meters from other people or animals.

Manufacturer information

DEWALT

Brand profile

Practical help

Common problems

Pump does not reach working pressure

Check for worn nozzle, fouled water filter, insufficient water supply, or air in the system. Ensure suction height from open containers is not over 0.5m.

Motor buzzes but fails to start

Check if mains voltage matches the data plate. Verify extension cable characteristics or contact an authorized service center.

No detergent sucked in

Dilute detergent if too dense, or flush the detergent circuit with clean water to remove restrictions.

Before use

  • Check that the power cable, high-pressure hose, and fittings are not damaged.
  • Ensure the water supply tap is turned on fully.
  • Check that the inlet filter (L) is clean.
  • Ensure the appliance is on a firm, stable surface.
  • Wear protective clothing and equipment (PPE).

Specs in practice

Protection class
Class I, indicating the appliance is equipped with a protective earthing conductor.

Model compatibility

  • Intended for non-professional (domestic) use.
  • Only use detergents supplied or recommended by the manufacturer.
  • Must be connected to a mains drinking water supply via a backflow preventer valve (EN 12729 type BA).