Roline 18U Wall Cabinet Basic Plus 600x600mm User Guide

Quick guide for the Roline 18U Wall Cabinet Basic Plus, covering installation steps, technical specifications, load capacity, and component features.

Table of contents

Manual images

Jump to the section

Quick guide from the manual

The Roline 18U Wall Cabinet Basic Plus is designed for flexible network cabling. It is delivered fully assembled and features a robust steel construction with a tempered glass front door. The cabinet is suitable for wall mounting, with an optional configuration for free-standing use using levelling feet or castors.

Roline 18U Wall Cabinet Basic Plus overview
Roline 18U Wall Cabinet Basic Plus overview

Installation

Wall mounting is performed in two primary steps:

  1. Secure the rear panel to the wall.
  2. Connect the main housing to the mounted rear panel.

The cabinet includes mounting material. Ensure the wall structure can support the cabinet's weight and the equipment load.

Device Features

Cabinet with side panel removed
Cabinet with side panel removed
Internal profile rails
Internal profile rails
  • Load Capacity: Maximum 80 kg.
  • Accessibility: Side panels feature a quick-release mechanism and are fully removable.
  • Cable Management: Punched cable inlets are located on both the roof and the base plate.
  • Ventilation: Includes slots for passive ventilation; the roof is prepared for the installation of optional fan modules.
  • Profile Rails: Galvanised L-shaped rails with 19-inch (482.6 mm) spacing, adjustable in depth.

Technical Specifications

  • Dimensions: 912 mm (H) x 600 mm (W) x 600 mm (D).
  • Rack Depth: Supports equipment depths between 320 mm and 450 mm.
  • Protection Class: IP20.
  • Weight: 24.7 kg (net).
  • Material: Steel frame with tempered glass front door.
  • Colour: RAL 7035 (Light grey).

Maintenance and Scope of Delivery

The cabinet is designed for passive cooling. Regularly check that ventilation slots are not obstructed. The scope of delivery includes the cabinet, an earthing cable set, two spanners, and assembly instructions.

Manufacturer information

ROLINE

Brand profile

Practical help

Common problems

Insufficient ventilation for high-heat equipment

The cabinet is designed for passive ventilation. If equipment generates significant heat, install an optional fan module in the roof cut-out.

Equipment does not fit depth-wise

Ensure your equipment depth is between 320 mm and 450 mm. The internal profile rails are adjustable in depth to accommodate different device sizes.

Before use

  • Verify the wall surface is suitable for supporting the 80 kg maximum load capacity.
  • Ensure the installation area allows for the removal of side panels for future maintenance.
  • Check that the required mounting hardware is present in the package.
  • Confirm the 19-inch rack spacing matches your network equipment.

Specs in practice

482.6 mm (19 inch)
The standard width for rack-mount networking equipment.

Images and diagrams

  • The cabinet features a removable front glass door and quick-release side panels for easy access to installed hardware.
  • Internal L-shaped rails are visible inside the cabinet, providing the mounting points for 19-inch equipment.

Model compatibility

  • Compatible with standard 19-inch rack-mount equipment.
  • Not soundproof; intended for standard office or server room environments.
  • Not suitable for outdoor use (IP20 rating).