Manual Motor Starter ABB MS132-0.25K
Quick guide for the ABB MS132-0.25K manual motor starter. Includes technical specifications, mounting requirements, and accessory compatibility.
Table of contents
Quick guide from the manual
The ABB MS132-0.25K is a compact 45 mm wide manual motor starter designed to manually switch motors on and off. It provides reliable protection against short-circuits, overloads, and phase failures without the need for a fuse. This device is suitable for both three-phase and single-phase applications.

Product Overview
The device features a rotary handle with clear switch position indication (ON/OFF/TRIP) and is lockable to prevent unauthorized changes. It includes a built-in disconnect function and temperature compensation.
Technical Specifications
- Rated Operational Current (Ie): 0.25 A
- Rated Operational Voltage: 690 V AC / 250 V DC
- Rated Service Short-Circuit Breaking Capacity (Ics): 100 kA at 400 VAC
- Trip Class: 10
- Degree of Protection: IP20
- Electrical Durability: 50,000 cycles
- Mechanical Durability: 100,000 cycles
Installation
The device is designed for mounting on a DIN rail. Ensure the following conditions are met:
- Mounting Rail: Compatible with TH35-15 (35 x 15 mm) and TH35-7.5 (35 x 7.5 mm) rails according to IEC 60715.
- Wire Connection: Uses Push-in spring terminals.
- Connecting Capacity: Supports flexible wires with ferrules (0.5 - 4 mm²), solid wires (1 - 2.5 mm²), and stranded wires (1 - 6 mm²).
- Wire Stripping Length: 12 mm.
- Mounting Distances: Maintain specific distances from conductive boards and other devices to ensure proper operation (e.g., 0 mm to 1.5 mm for conductive boards depending on voltage).
Accessories
The MS132-0.25K supports a wide range of accessories, including:
- Auxiliary contacts (e.g., HKF1-11, HK1-20)
- Signaling contacts (e.g., SK1-20, SK1-11)
- Shunt trips (e.g., AA1-24, AA1-230)
- Undervoltage releases (e.g., UA1-24, UA1-230)
- Busbars (e.g., PS1-2-0-65K)
- Enclosures and door mounting kits
Practical help
Common problems
Verify that the motor load matches the rated operational current (0.25 A) and check for short-circuits or phase failures in the circuit.
Ensure the rail is a standard TH35-15 or TH35-7.5 type according to IEC 60715.
Before use
- Verify the motor's rated current is within the 0.16 - 0.25 A range.
- Ensure the supply voltage does not exceed 690 V AC.
- Check that the wire size is compatible with the Push-in spring terminals (0.5 - 4 mm² for flexible with ferrule).
- Confirm the DIN rail type is TH35-15 or TH35-7.5.
- Ensure proper clearance distances are maintained from conductive boards.
Specs in practice
- Ie (Rated Operational Current)
- The current the device is designed to handle continuously (0.25 A).
- Ics (Rated Service Short-Circuit Breaking Capacity)
- The maximum fault current the device can interrupt while remaining operational (100 kA at 400 VAC).
- Trip Class 10
- The time-current characteristic defining the tripping time under overload conditions.
Model compatibility
- Compatible with various ABB accessories including auxiliary contacts, signaling contacts, and shunt trips.
- Suitable for both three-phase and single-phase applications.
- Requires terminal spacer TS1-M3-K for UL508 Type E compliance.
Manual page author
David Miller
Documentation analyst
Organizes user manual content into clear summaries, with attention to model details, product context, and everyday usability.