Sanela 19B Urinal Golem User Manual
Quick guide for the Sanela 19B Urinal Golem with radar flushing unit. Includes installation steps, parameter settings, eco-mode configurations, and maintenance tips.
Table of contents
Quick guide from the manual
This document provides installation and operational instructions for the Sanela 19B Urinal Golem with a 6V radar flushing unit. It covers technical requirements, parameter adjustments, and maintenance procedures.
Installation
Before installation, ensure you have read the safety instructions. The installation requires a water supply (G 1/2") and a waste pipeline (Ø 50 mm). Ensure the wall is prepared according to the technical drawing provided in the manual. Use the included mounting hardware to secure the unit.
- Ensure the water pressure is between 0.1 - 0.6 MPa.
- The sieve dimension must be ≤ 90 µm.
- Follow the numbered steps 1-13 in the manual for physical assembly and connection.
- The electronics activate 15 minutes after battery insertion, followed by a 1-minute automatic adjustment.
Operation and Eco Modes
The urinal features two eco-modes to optimize water consumption based on usage frequency:
- Eco Mode 1 (Break Mode): Suitable for schools or stadiums. If no usage is detected within the set time (default 300s), the system flushes automatically.
- Eco Mode 2 (Office Mode): Suitable for irregular usage. Alternates between "small" flushes (1s) to rinse and "large" flushes (3s) to clean the trap.
Parameter Settings
Parameters such as flushing time, activation time, and hygienic flush intervals can be adjusted using the SANELA Control application or the SLD 04 remote control. The hygienic flush interval can be set to OFF, 6, 8, 12, 24, 48, 72, or 168 hours.
Maintenance
Regular maintenance is recommended. Check the battery status periodically; the system provides audible indications for battery capacity. Replace batteries when necessary. Use recommended accessories like deodorising urinal screens (SLA 11 series) to maintain hygiene.
Manufacturer information
SANELA spol. s r. o.
Practical help
Common problems
Check the audible indication. If the system indicates 0% capacity, battery replacement is necessary.
Adjust the parameters using the SLD 04 remote control or the SANELA Control app.
Before use
- Verify water pressure is between 0.1 - 0.6 MPa.
- Ensure the sieve dimension is ≤ 90 µm.
- Check that the batteries are correctly inserted.
- Wait 15 minutes after battery insertion for the system to activate.
- Allow 1 minute for automatic adjustment after activation.
Specs in practice
- Water pressure
- Operating range 0.1 - 0.6 MPa.
- Hygienic flush interval
- Automatic flush to prevent odors during inactivity; adjustable from OFF to 168 hours.
Model compatibility
- Requires 6V power supply (batteries).
- Compatible with SLD 04 remote control for parameter adjustments.
- Compatible with SANELA Control application.