Sanela SLPN 07EB Stainless Steel Urinal User Guide
Quick guide for the Sanela SLPN 07EB stainless steel urinal, covering technical specifications, installation requirements, sensor operation, and maintenance parameters.
Table of contents
Quick guide from the manual
The Sanela SLPN 07EB is a wall-mounted stainless steel urinal featuring integrated electronics for automatic flushing. It is designed for vandal-resistant applications. The system detects the presence of a user within a range of up to 0.7 meters for at least 7.5 seconds, triggering a flush once the user leaves the sensing zone.
Device description and features
- Material: Stainless steel AISI 304 (1.4301) with a matte finish.
- Vandal-resistant design with mounting via a service opening and special screws.
- Automatic flushing: Occurs after the user leaves the sensing zone.
- Hygiene flush: Automatically flushes 24 hours after the last valve activation.
- Adjustable flush time: 0.5 to 15.5 seconds.
- Parameter adjustment: Requires the SLD 03 remote control.
Installation and components
The delivery includes the stainless steel urinal, flushing head, sensor head with electronics, electromagnetic valve, angle valve with filter, connection hoses, mounting set, siphon, and a battery holder with 4 AA alkaline batteries (1.5 V, 2700 mAh). The recommended height for the front edge of the urinal is 650 mm above the floor.
Technical specifications
- Power supply: 6V (4x AA alkaline batteries).
- Battery life: Approximately 2 years (based on 100 flushes per day).
- Power consumption: 3W.
- Sensor range: 0.6 - 0.75 m.
- Recommended operating pressure: 0.1 - 0.6 MPa.
- Water inlet: External thread G 1/2 inch.
- Dimensions: 550 x 350 x 325 mm.
- Weight: 8 kg.
Manufacturer information
SANELA spol. s r. o.
Practical help
Common problems
Check if the batteries are depleted (replace with 4x AA alkaline batteries) or if the sensor range is obstructed.
Use the SLD 03 remote control to adjust parameters.
Before use
- Ensure water pressure is between 0.1 and 0.6 MPa.
- Verify the installation height of the front edge is 650 mm above the floor.
- Check that the sensor area is clear of obstructions.
- Ensure the angle valve with filter is correctly installed.
Specs in practice
- Sensor range
- The distance (0.6 - 0.75 m) within which the urinal detects a user.
- Hygiene flush
- Automatic flush triggered every 24 hours to prevent odors if the urinal is not used.
- Power supply
- Operates on 6V provided by 4 AA batteries.
Model compatibility
- Compatible with SLD 03 remote control for parameter settings.
- Optional power supplies (SLZ series) available for 24V DC operation if battery power is not desired.
Manual page author
Emily Carter
User documentation editor
Prepares concise manual descriptions and highlights the most useful setup, operation, and maintenance information for readers.