This document provides essential information for the installation and operation of the Steinbach Silent Mini heat pump. The device is designed exclusively for heating or cooling water in private swimming pools. It must be operated outdoors and requires a sufficient water flow from your filter system.

Installation
Ensure the heat pump is placed on a stable, level, and waterproof surface with at least 2 meters of distance from the pool. Maintain the required minimum distances from walls or objects as specified in the manual. Connect the water pipes using the provided adapters and hose clamps. Ensure the power supply is protected by a residual current device (RCD) with a maximum of 30 mA.

Operation
The heat pump features three modes: Heating, Cooling, and Defrost. Use the control panel to switch between modes and set the desired water temperature (between +10°C and +45°C). The device includes a key lock that activates automatically after 60 seconds of inactivity; deactivate it by holding the Up and Down buttons for 3 seconds.
App Pairing
To control the heat pump via smartphone, download the Steinbach Silent Series app. Ensure your smartphone is connected to a 2.4 GHz WiFi network. Follow the pairing instructions in the app to connect the device.
Maintenance and Troubleshooting
Regularly clean the grille and heat exchanger fins to prevent debris buildup. If the error code E 03 appears, the water flow is too low; check your filter pump or adjust the bypass valve. For other errors, consult the troubleshooting table in the manual or contact the Steinbach support team.
Manufacturer information
Steinbach International GmbH
Practical help
Common problems
Water flow is too low. Increase flow rate using the bypass valve or check the filter pump.
Wait three minutes for the startup delay to pass, or ensure the water temperature is not already at the set target.
Wait for the automatic defrost function to activate.
If it is condensation, it is normal. If it is pool water, check all connections and adapters for tightness.
Before use
- Check for visible damage to the device and controls.
- Ensure all pipes and accessories are in perfect condition.
- Verify the inlet is not blocked.
- Ensure ventilation slots are clean and clear.
- Confirm the power supply is RCD protected (30 mA).
Specs in practice
- Water throughput
- Minimum 2,000 L/h required for proper operation.
- Salt concentration
- Must not exceed 0.5% (5 g/l or 5,000 ppm).
- Operating voltage
- 220-240 V~, 50 Hz single-phase.
Images and diagrams
- The heat pump must be operated with filtered water.
- Use the provided adapters and hose clamps to connect the water lines.
- The control panel allows mode selection, temperature setting, and WiFi pairing.
Model compatibility
- The Steinbach Silent Series app only supports 2.4 GHz WiFi networks.
- The device is for private outdoor use only, not commercial.