The Truper 102492-03-OK is a versatile battery charger designed to efficiently power your tools. A key feature of this unit is its ability to charge two batteries of different capacities simultaneously, providing convenience and saving time for users with multiple power tools. The device is engineered for reliability, but it requires adherence to specific safety and operational guidelines to ensure optimal performance and longevity.

Operating Instructions

To begin using the charger, connect the AC plug to a standard 127V mains socket. Upon connection, the charge status indicator lights will illuminate green, signaling that the device is ready for use. Insert the battery into the charger, ensuring it is properly aligned with the guide until it reaches the stop position. Once correctly inserted, the indicator light will change from green to red, confirming that the charging process has initiated. When the battery reaches full capacity, the indicator light will revert to green, and the red light will turn off. After the cycle is complete, it is recommended to disconnect the charger from the power source and remove the battery.

Safety and Battery Maintenance

Safety is paramount when handling electrical equipment. Only charge the specific types of batteries intended for this device, as using incompatible batteries may result in damage or explosion. Do not operate the charger in damp or humid conditions. To maximize the lifespan of your batteries, follow these maintenance recommendations: charge the battery to its full capacity before the first use and maintain full charges during regular operation. Avoid leaving the battery uncharged for more than three months, and ensure the battery is fully discharged at least once per month to maintain cell health.

Troubleshooting Battery Issues

The charger includes diagnostic features to help identify battery issues. If the red light flashes, it indicates that the battery is too hot; allow it to cool down until it reaches the proper temperature range for charging. If the red light remains on beyond the recommended charging time, or if the red and green lights flash alternately, the battery may be defective. In such cases, the battery should be replaced or inspected by a Truper Authorized Service Center.

Manufacturer information

TRUPER, S.A. DE C.V.

Brand profile

Practical help

Common problems

Red light flashes

Battery is overheated; wait for it to cool down to the proper temperature.

Red light stays on too long or red/green lights flash alternately

Battery is likely defective; replace it or contact a Truper Authorized Service Center.

Before use

  • Ensure the power source is 127V.
  • Check that the battery type is compatible with the charger.
  • Verify the environment is dry and free of moisture.
  • Charge the battery to full capacity before the first use.

Specs in practice

Input Voltage
127V AC mains power.
Indicator Green
Charger is ready or battery is fully charged.
Indicator Red
Charging is in progress.

Model compatibility

  • Only charge the specific type of battery indicated for this model.
  • Using incompatible batteries may cause them to burst.