This guide provides essential instructions for the Vevor 121010-12-331-08C inflatable yurt tent. Always ensure the assembly area is clean, well-lit, and free of sharp objects. The ideal inflation pressure for the tent is between 6 and 8 PSI. Do not over-inflate, especially during hot summer days, as air expansion can damage the air column. Always dry the tent completely before storage to prevent mildew.

Parts List

Included parts and accessories
Included parts and accessories
  • Organizer bags (x2)
  • Hand pump (x1)
  • Rain fly (x1)
  • Transparent door (x1)
  • Transparent windows (x2)
  • Ropes (x6)
  • Pocket (x1)
  • Pegs (x46, including 30cm pegs for the rain fly)
  • Self-complementing toolkit (x1)
  • Nozzle spare parts (x1)

Assembly Instructions

Step 1: Site PreparationClear the area of trash and sharp objects. Ensure the ground is level. Unfold the tent and insert stakes into the corners.

Site preparation and staking
Site preparation and staking
Inflation process
Inflation process
Rain fly installation
Rain fly installation
Additional installation photo from page 8
Additional installation photo from page 8

Step 2: Valve SetupThe tent features two external air valves. Ensure one valve is closed before beginning inflation. Check and tighten the deflation valve before use.

Step 3: InflationAttach the pump head to the valve. Inflate until the air column stands up fully. Do not exceed 6-8 PSI.

Step 4: AccessoriesInstall the transparent door and windows according to your needs.

Step 5: SecuringOn rainy days, attach the rain fly for better waterproofing. Tighten the valve cover and secure the tent using the provided guy ropes and pegs.

Folding and Storage

Step 1: DeflationUnscrew the valve nozzle to deflate the tent.

Folding the tent
Folding the tent

Step 2: PreparationRemove all ground pegs and stow the wind ropes. Spread the tent out flat.

Step 3: FoldingFold the sides toward the center, then fold in half (approx. 75cm). Note: Do not roll the tent from the side of the air vent.

Step 4: PackingPlace the folded tent into the organizer bag.

Safety Warnings

  • Do not sit or stand on the tent.
  • This product is not a toy; keep children away.
  • Do not exceed weight capacities.
  • Inspect the tent before every use; do not use if parts are damaged.
  • Do not assemble if tired or under the influence of alcohol/drugs.
  • Wear safety goggles and work gloves during assembly.

Manufacturer information

VEVOR

Brand profile

Practical help

Common problems

Tent air column bursts or is damaged

Do not over-inflate. In hot weather, reduce the inflation amount as air expands with heat.

Mildew growth

Always dry the product thoroughly before storing it.

Tent will not stand up

Ensure the inflation pressure is between 6 and 8 PSI.

Before use

  • Clear the assembly site of sharp objects and trash.
  • Ensure the ground is level and stable.
  • Check that all parts (pegs, ropes, pump) are present.
  • Inspect the tent for loose or damaged components.
  • Tighten the deflation valve before starting inflation.

Specs in practice

Inflation Pressure
6-8 PSI (pounds per square inch) is the recommended range.
Product Size
4000 x 3000 x 2200 mm.

Images and diagrams

  • Assembly Steps: Illustrates the sequence of site preparation, valve operation, inflation, and securing with ropes/pegs.
  • Folding: Shows the deflation process and how to fold the tent for storage.

Model compatibility

  • Use only on a flat, level, hard, and smooth surface.

Manual page author

Michael Turner

Technical manual editor

Reviews PDF manuals for structure, safety notes, and practical product details so readers can find the right information quickly.