findmanualpdf.com

Abbott i-STAT CG4+ Cartridge Discontinuance Notice

Important notice regarding the discontinuation of the Abbott i-STAT CG4+ cartridge (blue, 03P85-51). Includes transition guidance to the alternative white cartridge (03P85-25) and a comparison of specifications.

Table of contents

Important Notice Regarding i-STAT CG4+ Cartridge

Abbott Point of Care has announced the discontinuation of the i-STAT CG4+ cartridge (blue), list number 03P85-51. Shipment of this product will cease on June 30, 2026. Users may continue to use existing stock of the blue cartridge until the expiration date printed on the product label.

Transition to Alternative Cartridge

Facilities are advised to transition to the i-STAT CG4+ cartridge (white), list number 03P85-25. This alternative is compatible with the i-STAT 1 System and offers the same tests as the blue cartridge, with expanded capabilities.

Comparison of Cartridges

The white cartridge (03P85-25) provides several advantages over the discontinued blue cartridge (03P85-51):

Comparison of specifications between the discontinued blue cartridge and the alternative white cartridge.
Comparison of specifications between the discontinued blue cartridge and the alternative white cartridge.
  • pH: Wider reportable range (6.500 to 7.800) and support for capillary samples and non-anticoagulated matrices.
  • PCO2: Wider reportable range (5.0 to 130.0) and support for capillary samples and non-anticoagulated matrices.
  • PO2: Wider reportable range (5 to 700) and support for capillary samples and non-anticoagulated matrices.
  • Lactate: Reportable range remains unchanged.

When transitioning to the white cartridge, facilities should follow their established policies and procedures for validation testing. Ensure that all healthcare providers are informed of the change.

Support and Contact

For questions regarding this transition or for complete intended use and product information, please contact your local support representative or technical services at 1-844-256-9531. Additional information is available at the official website: www.globalpointofcare.abbott.

Manufacturer information

Abbott Laboratories

Brand profile

Practical help

Common problems

Discontinuation of blue cartridge (03P85-51)

Transition to the white cartridge (03P85-25) before June 30, 2026.

Before use

  • Check the expiration date on current blue cartridge labels.
  • Review facility validation policies for transitioning to the white cartridge.
  • Verify testing needs against the white cartridge specifications.
  • Inform healthcare providers of the transition.

Specs in practice

03P85-51 (Blue)
Discontinued cartridge for i-STAT 1 System.
03P85-25 (White)
Alternative cartridge with wider reportable ranges and expanded sample types.

Images and diagrams

  • The comparison table on page 1 details the differences in reportable ranges, sample types, and sample matrices between the blue and white cartridges.

Model compatibility

  • White cartridge (03P85-25) supports non-anticoagulated samples, unlike the blue cartridge.
  • White cartridge (03P85-25) supports capillary samples, unlike the blue cartridge.

Manual page author

Michael Turner

Technical manual editor

Reviews PDF manuals for structure, safety notes, and practical product details so readers can find the right information quickly.