Quick answer

  • The BEGA 24901K3 is a recessed ceiling luminaire requiring a 160mm opening and 120mm depth. It must be installed by a qualified electrician and is not suitable for heat-insulating materials. p. 1, 2

Key actions

  • Install the luminaire p. 2
  • Connect electrical wiring p. 2

Problems and fixes

Luminaire needs removal

Loosen the guide screws to retract the fixing claws.

p. 2
Show 3 more answers Show less

Maintenance and reset

  • Cleaning p. 3

Technical specifications

Parameter Value Meaning Pages
Voltage 220-240 V Operating voltage p. 1
IP Rating IP 65 Protection against dust and water p. 1
Luminaire Wattage 15.5 W Total power consumption p. 2

Where to find it in the PDF

  • Product Overview and Safety p. 1
  • Installation and Technical Data p. 2
  • Maintenance and Spare Parts p. 3
Table of contents

Quick guide from the manual

The BEGA 24901K3 is a recessed ceiling luminaire designed for indoor and outdoor use. Installation must be performed by a qualified electrician in accordance with national safety regulations. The luminaire must not be installed in heat-insulating material.

Installation

The installation requires a recessed opening of 160mm diameter and a minimum depth of 120mm. Ensure the ceiling has sufficient load-bearing capability.

Dimensions and installation diagram
Dimensions and installation diagram
  • Preparation: Ensure the ceiling opening is 160mm. If installing in plasterboard, reinforce the back of the ceiling cladding in the area of the claws.
  • Wiring: Connect the cable to a suitable connection box (not included). Connect the mains supply to the black (L), blue (N), and green-yellow (earth) leads. Ensure proper strain relief.
  • Mounting: Insert the luminaire housing into the opening. Use the two adjustable fixing claws. Tighten the Torx T15 screws evenly by hand. Do not use an electric screwdriver.
  • Removal: To remove, loosen the guide screws to retract the fixing claws.

Maintenance and Cleaning

Clean the luminaire regularly using solvent-free cleaners. Do not use high-pressure cleaners. Important: Do not remove the desiccant bag located inside the luminaire housing, as it is required to absorb residual moisture.

Technical Specifications

  • Protection Class: IP 65 (dust-tight and protected against water jets).
  • Safety Class: I.
  • Voltage: 220-240 V, 0/50-60 Hz.
  • Luminaire Connected Wattage: 15.5 W.
  • Module Connected Wattage: 13.7 W.
  • Cable: H05RN-F 3G1, 0.5m length.

Manufacturer information

BEGA

Brand profile

Practical help

Common problems

Luminaire is loose in the ceiling

Ensure the fixing claws are properly engaged and tighten the Torx T15 screws evenly by hand.

Moisture accumulation inside

Ensure the desiccant bag inside the housing is not removed; it is essential for moisture control.

Before use

  • Verify the ceiling opening diameter is exactly 160mm.
  • Ensure the installation depth is at least 120mm.
  • Confirm the ceiling material is not heat-insulating.
  • Check that the ceiling has sufficient load-bearing capacity.
  • Ensure a suitable connection box is available for wiring.
Show more Show less

Specs in practice

Safety Class I
The device must be connected to a protective earth conductor.

Images and diagrams

  • The diagram shows the luminaire dimensions: 175mm outer diameter, 160mm installation opening, and 120mm installation depth.

Model compatibility

  • Not suitable for installation in heat-insulating materials.

Manual page author