Cleaning Instructions for Ecolab 116A X-ray Protection Materials
A comprehensive guide for the daily cleaning and maintenance of Optibelt ELASTOMIT-R 116A and 122A X-ray protection curtains used in food industry detection systems.
Table of contents
Quick guide from the manual
This document provides non-binding cleaning recommendations for Optibelt ELASTOMIT-R 116A and 122A X-ray protection curtains. Regular daily cleaning is essential to prevent microbiological growth. Always perform your own material tests before applying cleaning agents, as this guide does not replace local food industry hygiene regulations.
Cleaning procedures
The cleaning process follows a foam-based surface cleaning method. The curtain must be removed from the system before cleaning.
- Preparation: Remove the curtain from the X-ray detection system.
- Removal of coarse dirt: Use a puller or a soft, lint-free cloth (paper or microfiber) to collect and dispose of coarse residues.
- Rinsing: Rinse with water (50–60°C, approx. 5 bar) from top to bottom.
- Lathering: Apply Topactive 500 or 200 (3–5% concentration, 50–60°C, approx. 5 bar) for 20 minutes. Foam systematically from bottom to top.
- Rinsing: Rinse with water (50–60°C, approx. 5 bar) while wiping with a soft cloth to remove dissolved residues.
- Disinfection: Apply P3-topax 990 or Topactive OKTO (1–3% concentration, approx. 5 bar) for 10–20 minutes from top to bottom.
- Final Rinsing: Rinse thoroughly with water (50–60°C, 5 bar) until no visible residue remains.
Safety and maintenance
Workplace safety: Always wear required protective equipment. Never mix different cleaning agents or disinfectants. Do not use aggressive substances such as high-dose alcohols, acetone, benzine, or high-pressure cleaning equipment, as these can damage the material.
Manufacturer information
Ecolab Inc.
Practical help
Common problems
Ensure regular daily cleaning and prevent residues from drying on the surface.
Avoid using high-pressure cleaners, brushes, or aggressive chemicals like acetone or high-dose alcohols.
Before use
- Remove the curtain from the X-ray system.
- Verify the cleaning agent concentration (3-5% for lathering, 1-3% for disinfection).
- Ensure water temperature is between 50-60°C.
- Wear appropriate personal protective equipment.
- Check the curtain for cleanliness after the process.
Specs in practice
- Topactive 500
- Liquid, acidic cleaning agent for TFC hygiene processes.
- Topactive 200
- Liquid, alkaline cleaning agent for TFC hygiene processes.
- Topactive OKTO
- Liquid, acidic, foamable disinfectant based on peracids.
- p3-Topax 990
- Liquid, neutral foam disinfectant based on alkymine acetate.
Model compatibility
- Applies specifically to Optibelt ELASTOMIT-R 116A and 122A with blue rubber surfaces.
- Not all detergents are suitable for all materials; perform material testing in advance.