findmanualpdf.com

Installation Manual for DucoSun Cubic InsertFit 200x48 / 300x48 Sun Shading System

Installation guide for the DucoSun Cubic InsertFit 200x48 and 300x48 external aluminum sun shading system. Includes technical specifications, material details, and step-by-step installation instructions.

PDF source: NL · summary: English

Quick answers from the manual

Quick answer

  • The DucoSun Cubic InsertFit is an external aluminum sun shading system with fixed rectangular louvers and invisible mounting, suitable for vertical or horizontal installation. p. 1

Key actions

  • Install the system using the provided nut plates and mounting tool to secure the louvers. p. 3

Technical specifications

Parameter Value Meaning Pages
Cubic InsertFit 200x48 (Beugel 120) 5070 mm Maximum span for vertical louvers with 800 Pa load. p. 2
Cubic InsertFit 300x48 (Beugel 120) 5435 mm Maximum span for vertical louvers with 800 Pa load. p. 2
Show 1 more answers Show less

Where to find it in the PDF

  • System Description and Models p. 1
  • Materials and Technical Data p. 2
  • Installation Instructions p. 3
Table of contents

Important Information

The DucoSun Cubic InsertFit is an external aluminum sun shading system designed for vertical or horizontal installation. It features fixed rectangular louvers and an invisible mounting system, ensuring a seamless integration into the facade without visible screws. The system must be dimensioned according to local wind loads and effective spans, in accordance with applicable Eurocodes.

System Description

The system consists of the following main elements:

  • Louver: Available in 200 mm (Cubic InsertFit 200x48) and 300 mm (Cubic InsertFit 300x48) heights, with a width of 48 mm.
  • Finishing Profile: An InsertFit click profile that ensures invisible mounting.
  • Side Plate (Type I): Used to close the louver ends for an aesthetic finish.
  • Mounting Brackets (Optional): Load-bearing supports available in 40 mm, 80 mm, and 120 mm widths.

Technical Specifications

Materials:

  • Louvers and finishing profile: Aluminum EN AW-6063 T66 (EN 573-3).
  • Side plate: Aluminum.
  • Fasteners: Stainless steel (AISI 304).
  • Finishing: Natural anodization (15–20 μm) or Polyester powder coating (60–80 μm).

Fire Reaction: A2-s1,d0 according to EN 13501-1 (non-combustible, very limited contribution to fire, very low smoke production).

Installation

With Mounting Brackets:

  1. Place the nut plates in the louver using the mounting tool and lock them in the desired position.
  2. Screw the mounting bracket onto the louver.
  3. Prepare the finishing profile and click it onto the louver to hide visible fixings.
  4. Screw the side plates (Type I) into the screw channels of the louver.
  5. Screw the louvers with mounting brackets onto the provided attachment points of the support structure.

Without Mounting Brackets:

  1. Place the nut plates in the louver using the mounting tool and lock them in the desired position.
  2. Screw the louvers directly onto the provided attachment points of the support structure.
  3. Prepare the finishing profile and click it onto the louver profile to hide visible fixings.
  4. Screw the side plates (Type I) into the side plates of the louver.

Compliance

The system complies with the following standards: Qualicoat Seaside type A, Qualanod, EN 573 (EN AW-6063 T66 and EN AW-6060 T66), EN 1990, EN 1991, EN 1999, and EN 13501-1.

Manufacturer information

Duco Ventilation & Sun Control NV

Brand profile

Practical help

Common problems

Incorrect system dimensioning

The system must be dimensioned based on project-specific wind loads and effective spans according to Eurocodes.

Before use

  • Verify the load-bearing structure is suitable for the installation.
  • Select the correct louver size (200x48 or 300x48).
  • Determine if mounting brackets are required (40, 80, or 120 mm).
  • Ensure all fasteners are stainless steel (AISI 304) as specified.
Show more Show less

Specs in practice

EN AW-6063 T66
The specific aluminum alloy used for the louvers and finishing profiles.

Model compatibility

  • System must be dimensioned according to local wind loads and effective spans.
  • Compatible with vertical or horizontal installation at a 0° inclination.