Quick answer

  • The Hoftronic CALI LED High Bay must be installed by a qualified electrician with the power supply disconnected. It supports hook or bracket mounting and requires grounding. p. 2, 3, 11

Key actions

  • Mounting the fixture p. 3
  • Wiring the fixture p. 2

First start

  • Ensure the construction is strong enough to support the high bay and that the product is properly grounded before connecting to power. p. 2, 11
Show 4 more answers Show less

Problems and fixes

Product turns off during operation

The product has an automatic thermal shutdown feature. It will turn on again once it cools down.

p. 2

Maintenance and reset

  • Clean only with soft and dry cloths. Do not use chemical detergents. p. 11

Technical specifications

Parameter Value Meaning Pages
IP Rating IP65 Dust and water protection p. 1
Impact Rating IK10 Impact resistance p. 1

Where to find it in the PDF

  • Safety and Wiring p. 2
  • Installation p. 3
  • Accessories p. 4
Table of contents

Manual images

Click an image to enlarge

Quick Guide

The Hoftronic CALI LED High Bay is a professional lighting fixture designed for commercial and industrial indoor use. This manual covers the installation, safety requirements, and maintenance of the product. Ensure all installation work is performed by a qualified electrician with the power supply disconnected.

Hoftronic CALI LED High Bay
Hoftronic CALI LED High Bay

Safety Instructions

Failure to follow these instructions may result in fire, burns, electric shock, or physical injury. Please adhere to the following:

  • Power Supply: Ensure AC/Mains power is disconnected and cannot be reconnected during installation.
  • Qualified Personnel: Installation must be performed by a qualified electrician in compliance with local electrical and safety regulations.
  • Grounding: The product must be grounded.
  • Usage: For indoor use only. Do not cover the product.
  • Thermal Protection: The housing may become hot during operation. The product features automatic thermal shutdown if the temperature becomes too high; it will turn on automatically once cooled.
  • Restrictions: Not for use by minors or individuals with mental disabilities.
  • Cable: The external flexible cable cannot be replaced; if damaged, the luminaire must be destroyed.

Installation

The luminaire can be installed using two methods:

Bracket mounting procedure
Bracket mounting procedure

Hook Mounted

  1. Lock the ring onto the luminaire.
  2. Hang the luminaire on a secure hook capable of supporting the weight (Chain load capacity > 30kg).

Bracket Mounted

  1. Attach the trunnion mount bracket to the ceiling or structure.
  2. Secure the luminaire to the bracket using the provided screws.
  3. Ensure proper mechanical fastening before use.

Wiring

Connect the wires according to the standard electrical color coding:

Wiring diagram
Wiring diagram
  • L (Live): Brown
  • N (Neutral): Blue
  • Ground: Yellow/Green

Ensure the connection is secure and the cable diameter is appropriate for the cable gland to maintain the IP65 protection level.

Maintenance

  • Perform maintenance only when the power is off and the product has cooled down.
  • Clean using only soft, dry cloths. Do not use chemical detergents.
  • The product is non-demountable and not suitable for independent repairs.

Optional Accessories

The following accessories are available for the CALI LED High Bay:

  • Mounting Bracket (Article No. 4408879)
  • Lenses (60° and 90° options for 80W-120W and 150W-200W models)
  • Microwave & Daylight Sensor (Article No. 4408886)

Manufacturer information

Hoftronic

Brand profile

Practical help

Common problems

Product shuts down automatically

This is a safety feature. The product will automatically turn back on once it has cooled down.

Housing is hot

The housing may become hot after operation; this is normal. Ensure free air access and do not cover the product.

Before use

  • Ensure AC/Mains power is disconnected.
  • Verify the installation surface/construction is strong enough to support the high bay.
  • Ensure the product is grounded.
  • Check for proper mechanical fastening.
  • Ensure the cable diameter matches the cable gland to maintain IP65 rating.
Show more Show less

Images and diagrams

  • Wiring diagram: Brown wire to L, Blue wire to N, Yellow/Green wire to Ground.
  • Hook mounting: Requires a chain with a load capacity of at least 30kg.

Model compatibility

  • Indoor use only.
  • Not suitable for independent repairs.
  • External flexible cable cannot be replaced.