The Sanela SLS 02PTAB is a piezo-controlled shower system with a thermostatic mixer. This document covers the installation, operation, and parameter adjustment of the device. Key requirements include a water pressure of 0.1 - 0.6 MPa and a sieve mesh size of ≤ 90 µm. The system is powered by batteries.

Installation

Before installation, ensure you have read the attached safety instructions. The installation process involves:

  • Preparing the wall recess (0-6 mm depth for tiling).
  • Connecting hot and cold water supplies to the G 1/2" inlets.
  • Mounting the control box using the provided brackets and screws.
  • Installing the batteries (4x AA 1.5V) into the battery pack.
  • Connecting the piezo button cable to the solenoid valve.
  • Final assembly of the cover plate and thermostatic handle.

Operation and Settings

The system is operated via a piezo button. Parameters can be adjusted using the SLD 04 remote control (optional accessory). Default factory settings include:

  • Automatic stop: 120 seconds.
  • Hygienic flush interval: OFF.
  • Hygienic flush duration: 5 seconds.

The SLD 04 remote allows for adjusting the automatic stop time (10-310s), hygienic flush interval (OFF/6/8/12/24/48/72/168h), and flush duration (5-1200s).

Maintenance

Regular maintenance is recommended. To shut off water for maintenance, use the integrated shut-off valves. Battery status is indicated by the electronic system; if the system indicates low capacity, replace the batteries immediately. For technical support, visit www.sanela.eu/service.

Manufacturer information

SANELA spol. s r. o.

Brand profile

Practical help

Common problems

Low battery indication

Replace all 4 AA alkaline batteries when the system indicates necessary battery exchange.

Water flow issues

Check if the water pressure is within the 0.1 - 0.6 MPa range and ensure the sieve is clean (mesh size ≤ 90 µm).

Before use

  • Verify water pressure is between 0.1 and 0.6 MPa.
  • Ensure the sieve mesh size is ≤ 90 µm.
  • Install 4 fresh AA 1.5V alkaline batteries.
  • Confirm all electrical connections between the piezo button and solenoid valve are secure.
  • Read the separate safety instructions provided with the product.

Specs in practice

Automatic stop
The duration the water flows after pressing the button (factory default 120s).
Hygienic flush
Automatic water flow at set intervals to prevent Legionella growth.
Pressure range
Operating water pressure must be 0.1 - 0.6 MPa for proper function.

Model compatibility

  • Requires SLD 04 remote control for changing advanced parameters.
  • Compatible with SLA 36 battery set (4x AA 1.5V, 2700 mAh).