The Alorair PureCare 1350IG is an air filtration system designed to circulate air and filter wood or other non-metallic dust. Important: Installation requires at least two people. The unit must be installed at least 7 feet above the floor and at least 3 feet away from corners or heating/air vents. Do not operate the machine without a filter installed.

Specifications

  • Power: 115V / 60 Hz, 1.5 Amps max.
  • Airflow: 1050 / 1350 CFM.
  • Filters: MERV-11 (90% 3-10 μm, 85% 1 μm).
  • Remote Control Distance: Max 27 ft.
  • Weight: 27 lbs.
  • Dimensions: 20.5" x 20.5" x 9.8".

What's in the Box

  • PureCare 1350 / 1350IG unit
  • MERV-11 Filters (x4)
  • Hanging hardware (Screws, hanging pieces, expansion bolts, nuts, screw hooks, tapping screw hooks, hanging chains)
  • Remote controller with AAA batteries

Safety Rules

To avoid injury and damage, follow these safety precautions:

  • Do not use power tools in the presence of flammable liquids or gases.
  • Keep bystanders at a safe distance.
  • Wear a face mask or dust mask to protect against dust.
  • Always unplug the unit before making adjustments, changing parts, or cleaning.
  • Ensure the unit is properly grounded. Do not modify the plug.
  • Do not use in environments with poisonous gases, fumes, or chemical risks.

Installation

The unit requires assembly before use. Do not discard the carton until fully assembled.

Hanging installation assembly details
Hanging installation assembly details
Ceiling placement overview
Ceiling placement overview
Mounting bracket installation
Mounting bracket installation

Method 1: Hanging Installation

  1. Thread the locknuts onto the hangers.
  2. Thread a hanger into each of the four mounting holes on the top of the air filter cabinet.
  3. Tighten the catch locknut against the cabinet top.
  4. Mark the ceiling (recommended 23.6" x 23.6" spacing) and drill holes using a 3mm drill bit.
  5. Install wood screw hooks into the building support structure.
  6. Attach chains to the hooks and connect the hangers to the chains.
  7. Ensure the unit is level and at least 7 feet above the floor.

Method 2: Bracket Installation

  1. Install 4 mounting brackets onto the equipment using M4 screws.
  2. Measure the distance between brackets (recommended 18.9" x 18.9" spacing) and mark the ceiling.
  3. Drill holes using a 10mm drill bit for expansion screws.
  4. Lift the equipment and secure it to the ceiling using the expansion screws and nuts.

Operation

The unit can be operated via the control panel or the remote control. It features a power-off memory function.

Control panel and remote control layout
Control panel and remote control layout
  • Power: Press the ON/OFF button to start or stop the unit.
  • Speed: Press the SPEED button to toggle between LOW and HIGH settings.
  • Ionizer: Press the ionizer button on the remote to toggle the feature (Note: PureCare 1350 does not have this feature).
  • Timer: Press the timer shutdown button to set a shutdown time from 1H to 9H.

Maintenance

Warning: Always unplug the unit before changing filters or servicing.

Changing the filters
Changing the filters
  • Check filters periodically. Clogged filters reduce airflow and increase noise.
  • To change filters: Power off the device, remove the old filter, and insert the new one.
  • Wear a mask and gloves when changing filters.
  • If the remote control range is short, replace the batteries and clean the infrared receiver on the control panel.

Manufacturer information

AlorAir Solutions Inc.

Brand profile

Practical help

Common problems

Excessive noise

The filter may be blocked. Replace the filter.

Unit does not power on

Check if the power circuit is overloaded or if the power protector has tripped.

Remote control not working

Replace the AAA batteries and ensure the infrared receiving opening on the control panel is not blocked.

Before use

  • Ensure a 115V / 60 Hz power source is available.
  • Verify that all four MERV-11 filters are installed.
  • Ensure two people are available for the installation process.
  • Confirm the installation location is at least 7 feet above the floor.
  • Check that the location is at least 3 feet away from corners or air vents.

Specs in practice

CFM (1050/1350)
Cubic Feet per Minute; indicates the volume of air the unit can process.

Images and diagrams

  • Fig 1: Details the assembly of the hanger and locknut onto the air filter cabinet.
  • Fig 2: Illustrates the ceiling hanging installation method using chains.
  • Fig 3: Illustrates the mounting bracket installation method.
  • Fig 4 & 5: Shows the layout of the control panel and the remote control buttons.

Model compatibility

  • Only use accessories approved by Alorair.
  • Do not mount the air filter to non-structural surfaces like drywall or false ceiling grids.
  • The unit is for indoor use only; do not expose to rain or damp locations.