findmanualpdf.com

User Manual for BEGA 24087 Wall Luminaire

Comprehensive user guide for the BEGA 24087 wall luminaire. Includes installation instructions, wiring details for DALI control, maintenance procedures, and technical specifications.

PDF source: Français · summary: English

Quick answers from the manual

Quick answer

  • The BEGA 24087 is a wall luminaire with shielded light (2x90°). It is IP65 rated, DALI-controllable, and requires installation by a qualified electrician. Always keep the desiccant pouch inside the housing. p. 1, 2

Key actions

  • Install the desiccant pouch p. 2
  • Connect DALI control p. 2

First start

  • Lead the mains supply cable through the cable entry, make earth connection, and connect DALI if required. p. 2
Show 4 more answers Show less

Problems and fixes

Moisture accumulation

Do not remove the desiccant bag; it is required to absorb residual moisture.

p. 2

Maintenance and reset

  • Clean regularly with solvent-free cleaners; do not use high-pressure cleaners. p. 2

Technical specifications

Parameter Value Meaning Pages
Luminaire connected wattage 11.5 W Power consumption of the luminaire p. 2
Protection class IP 65 Dust-tight and protection against water jets p. 1
Impact strength IK06 Protection against mechanical impacts < 1 Joule p. 1

Where to find it in the PDF

  • Technical Data and Dimensions p. 1
  • Installation and Maintenance p. 2
  • Spare Parts p. 3
Table of contents

Quick Guide from the Manual

The BEGA 24087 is a wall luminaire designed for interior and exterior use, featuring shielded light with a 2x90° emission. It is IP65 rated (dust-tight and protected against water jets) and IK06 impact resistant. Installation must be performed by a qualified electrician. A critical step during installation is the placement of the included desiccant pouch inside the housing to prevent moisture accumulation.

Technical dimensions of the BEGA 24087 wall luminaire.
Technical dimensions of the BEGA 24087 wall luminaire.

Product Description

The luminaire is constructed from aluminium alloy, aluminium, and stainless steel with BEGA Unidure® coating technology. It features a safety glass cover and an optical silicone lens. The unit is DALI-controllable and includes BEGA Thermal Control® for temporary thermal regulation to protect sensitive components.

Installation

Installation must be carried out by a qualified electrician in accordance with national safety regulations.

  • Preparation: Use a 3mm hexagon socket wrench to undo the screw through the opening in the luminaire housing and lift the top part.
  • Mounting: Lead the mains supply cable through the cable entry in the luminaire base. Fix the base to the mounting surface using the two enclosed screws diagonally.
  • Wiring: Make the earth conductor connection and the electrical connection. For digital control, use the DA, DA terminal. If this terminal is not used, the luminaire operates at full light output.
  • Finalizing: Insert the desiccant pouch (removed from foil packaging) into the position marked by the red label. Push the plug into the coupler until it stops. Ensure the gasket is positioned correctly, then install the luminaire top and tighten the screw.

Maintenance and Cleaning

Clean the luminaire regularly using solvent-free cleaners to remove dirt and deposits. Do not use high-pressure cleaners. Important: Do not remove the desiccant bag from the luminaire housing, as it is required to absorb residual moisture.

LED Module Replacement

The LED module can be replaced by qualified persons using standard tools. Ensure the system is disconnected from power before opening. The light colour and output of replacement modules correspond to the original. Always inspect and, if necessary, replace the luminaire gaskets when replacing the module. A defective glass cover must be replaced.

Technical Specifications

  • Connected Wattage: 11.5 W (Luminaire), 10 W (Module)
  • Protection Class: IP 65 (Dust-tight and water jet protected)
  • Impact Strength: IK06 (< 1 Joule)
  • Control: DALI-controllable
  • Ambient Temperature: ta max = 50 °C
  • Weight: 1.4 kg

Manufacturer information

BEGA

Brand profile

Practical help

Common problems

Moisture inside the luminaire

Ensure the desiccant pouch was not removed during installation and that the gasket is correctly positioned.

Luminaire not dimming via DALI

Verify that the control wires are correctly connected to the DA, DA terminals.

Before use

  • Ensure installation is performed by a qualified electrician.
  • Verify the mounting surface is suitable for the luminaire.
  • Check that the desiccant pouch is included in the housing.
  • Ensure the gasket is correctly positioned before closing the luminaire.
  • Verify the mains supply cable diameter is between 7-12 mm.
Show more Show less

Specs in practice

BEGA Thermal Control
Temporary thermal regulation to protect components without switching off the light.

Images and diagrams

  • The technical drawing shows the mounting plate with 4 holes (86x86mm) and the cable entry points.
  • The wiring section explains the use of the DA, DA terminal for digital control.

Model compatibility

  • Compatible with DALI control systems.
  • Requires standard tools for installation and module replacement.

Manual page author

Emily Carter

User documentation editor

Prepares concise manual descriptions and highlights the most useful setup, operation, and maintenance information for readers.