findmanualpdf.com

Installation and User Guide for BEGA 23256.3 Wall Luminaire

Comprehensive installation and user guide for the BEGA 23256.3 indoor wall luminaire. Includes mounting instructions, technical specifications, safety guidelines, and LED module replacement procedures.

Quick answers from the manual

Quick answer

  • The BEGA 23256.3 is an indoor wall luminaire. Installation must be performed by a qualified electrician, requiring a 350 mm clearance for maintenance and 460 mm spacing for mounting holes. p. 1, 2

Key actions

  • Installation p. 2
  • LED Module Replacement p. 3

Problems and fixes

Luminaire not functioning

Ensure the system is connected to power and the insulation housing is properly engaged.

p. 2
Show 3 more answers Show less

Maintenance and reset

  • Replace LED module p. 3

Technical specifications

Parameter Value Meaning Pages
Power 15.5 W Luminaire connected wattage p. 2
Protection Class IP 44 Splash water protection p. 1
Color Temperature 3000 K Warm white light p. 2

Where to find it in the PDF

  • Product Overview and Safety p. 1
  • Technical Data and Installation p. 2
  • Maintenance and Spare Parts p. 3
Table of contents

Quick guide from the manual

The BEGA 23256.3 is an indoor wall luminaire featuring hand-blown opal glass and a metal housing. Installation and commissioning must be performed by a qualified electrician in accordance with national safety regulations. Ensure a minimum clearance of 350 mm is maintained around the removable cap to allow for mounting and dismantling of the glass cylinder.

Dimensions of the BEGA 23256.3 wall luminaire.
Dimensions of the BEGA 23256.3 wall luminaire.

Product Description

This luminaire is designed for interior lighting tasks requiring soft and uniform light distribution. It features an insulation housing with a cable entry for mains supply cables up to 10.5 mm in diameter. The unit includes a BEGA Thermal Switch to protect temperature-sensitive components via temporary thermal shutdown.

Installation

Preparation: Ensure the mounting surface is suitable for the luminaire's weight of 2.1 kg. Drill mounting holes with a spacing of 460 mm.

Electrical Connection:

  • Open the insulation housing by pulling it apart.
  • Strip the mains supply cable to a maximum of 15 mm.
  • Lead the cable through the entry into the insulation housing.
  • Make the earth conductor connection and the electrical connection.
  • Connect both parts of the insulation housing until they audibly engage.
  • Ensure the outer coating of the cable is fully enclosed by the compression nipple.

Final Assembly: Fix the luminaire to the mounting surface using the provided or suitable fixing material. Place the glass into the housing, close with the cap, and screw in the knob.

Maintenance and LED Replacement

The LED module can be replaced by qualified persons using standard tools. To replace the module:

  1. Disconnect the system from the power supply.
  2. Loosen the lateral knob, remove the cap, and take out the glass.
  3. Follow the specific installation instructions provided with the replacement LED module.
  4. Reassemble the luminaire by inserting the glass, closing the cap, and securing it with the knob.

If the glass is defective, it must be replaced. Do not touch the light output opening of the LED directly during installation or relamping.

Technical Specifications

  • Protection Class: IP 44 (Protected against granular foreign bodies ≥ 1 mm and splash water)
  • Impact Strength: IK02 (Protection against mechanical impacts < 0.2 joules)
  • Safety Class: I
  • Mains Voltage: 220-240 V, 0/50-60 Hz
  • Module Connected Wattage: 13.4 W
  • Luminaire Connected Wattage: 15.5 W
  • Color Temperature: 3000 K
  • Color Rendering Index (CRI): > 90
  • Module Luminous Flux: 2210 lm
  • Luminaire Luminous Flux: 1643 lm

Manufacturer information

BEGA

Brand profile

Practical help

Common problems

Difficulty removing the glass cylinder

Ensure a minimum clearance of 350 mm is maintained between the removable cap and the wall.

LED module failure

The module can be replaced by a qualified person. Ensure the system is disconnected from power before attempting replacement.

Before use

  • Verify that the installation is performed by a qualified electrician.
  • Ensure the mounting surface can support the luminaire weight (2.1 kg).
  • Confirm 350 mm clearance is available for maintenance access.
  • Check that the mains supply cable diameter is up to 10.5 mm.
  • Ensure the earth connection is properly established.
Show more Show less

Specs in practice

Safety Class I
Requires connection to the protective earth conductor.
BEGA Thermal Switch
Temporary thermal shutdown to protect temperature-sensitive components.

Images and diagrams

  • The dimension diagram shows the 460 mm spacing for fixing holes and the 700 mm total length.
  • The insulation housing diagram illustrates the cable entry and the connection terminal.

Model compatibility

  • Requires BEGA replacement modules for maintenance.
  • Compatible with standard 220-240 V, 50-60 Hz mains supply.

Manual page author

David Miller

Documentation analyst

Organizes user manual content into clear summaries, with attention to model details, product context, and everyday usability.