findmanualpdf.com

User Manual for Danfoss CF-RS Standard Room Thermostat

Quick guide for the Danfoss CF-RS Standard Room Thermostat. Learn how to install, pair with a Master Controller, mount, and troubleshoot your thermostat.

Table of contents

Quick Guide

This document provides instructions for the Danfoss CF-RS Standard Room Thermostat. Before use, ensure you remove the battery strips to activate the device. During the pairing process with the Master Controller, keep the thermostat within 1.5 meters of the controller. The thermostat is designed for wireless communication and can be assigned to multiple outputs if required.

Functional Overview

The thermostat features a front-mounted turning knob and push button for operation, with a red LED indicator located behind the cover. The LED provides status feedback:

  • Permanent light: ON
  • No light: OFF
  • Slow flashing: Flashes
  • Fast flashing: Flickers

The back of the unit contains the back plate, battery compartment, and mounting points.

Installation

To pair the thermostat with the Master Controller:

  1. Activate the Install mode on the Master Controller using the menu selection button. The Install LED will flash.
  2. Press OK on the Master Controller to activate. The Install LED will turn ON.
  3. Press the push button on the Room Thermostat. The LED on the thermostat and the Master Controller will flicker during communication.
  4. Select the desired output on the Master Controller using the output selection button and confirm with OK.
  5. The installation status is confirmed when the thermostat LED turns OFF. If it flashes 5 times, the installation was not successful.

Transmission Test

To verify the connection:

  1. Press the push button on the Room Thermostat. The LED will turn ON.
  2. If the link is satisfactory, the LED will turn OFF.
  3. If the link is unsatisfactory, the LED will flash 5 times.
  4. If there is no link, try relocating the thermostat or installing a Repeater Unit (CF-RU) between the Master Controller and the thermostat.

Mounting

For optimal performance, install the thermostat in a location that avoids direct sunlight, drafts, and heat sources such as televisions or other heaters. Use the provided back plate and screws to mount the unit to the wall.

Uninstallation

To remove the thermostat from the Master Controller:

  1. Activate the Uninstall mode on the Master Controller.
  2. Select the output to be removed using the output selection button.
  3. Confirm the removal with the OK button.

Specifications

  • Temperature setting range: 5-35°C
  • Transmission frequency: 868.42 MHz
  • Transmission range: Up to 30m in normal buildings
  • Battery: 2x AA Alkaline, 1.5V
  • Battery lifetime: 3-4 years
  • IP class: 21

Troubleshooting

  • LED flashes every 5 minutes: Low battery.
  • LED flashes every 30 seconds: Critical low battery.
  • LED flashes 5 times: Installation or Link Test is unsatisfactory.

Manufacturer information

Danfoss A/S

Brand profile

Practical help

Common problems

LED flashes 5 times

The installation or link test is unsatisfactory. Ensure the thermostat is within range or consider using a Repeater Unit (CF-RU).

LED flashes every 5 minutes

Battery level is low. Replace the batteries.

LED flashes every 30 seconds

Battery level is critically low. Replace the batteries immediately.

No link connection

Relocate the thermostat to a different position in the room or install a Repeater Unit (CF-RU) between the Master Controller and the thermostat.

Before use

  • Remove the battery strips to activate the thermostat.
  • Ensure the Master Controller is in Install mode.
  • Keep the thermostat within 1.5 meters of the Master Controller during the pairing process.
  • Ensure the 24V actuator is mounted and the red clip is removed (if applicable).

Specs in practice

Temperature setting range
The thermostat can be set between 5°C and 35°C.
Transmission frequency
Operates at 868.42 MHz for wireless communication.

Model compatibility

  • Compatible with Danfoss Master Controller (CF-MC).
  • Can be used with Repeater Unit (CF-RU) to extend transmission range.

Manual page author