Installation and User Guide for Danfoss TPOne-S Thermostat

Comprehensive installation and user guide for the Danfoss TPOne-S programmable room thermostat. Includes wiring diagrams, mounting instructions, setup wizard, comfort mode configuration, and troubleshooting.

Table of contents

Manual images

Click an image to enlarge

Quick guide from the manual

This document provides installation and operation instructions for the Danfoss TPOne-S Electronic Programmable Room Thermostat. It is intended for both qualified installers and end-users. Key procedures include initial setup, RF pairing, and configuration of heating schedules.

Mounting and Positioning

Proper positioning is critical for RF performance. Ensure the following:

Thermostat positioning guidelines
Thermostat positioning guidelines
  • Mount the thermostat at a height of approximately 1.5m from the floor.
  • Avoid areas with draughts, direct sunlight, or heat sources like radiators.
  • Keep the receiver at least 30cm away from metal enclosures or appliances.
  • Ensure there are no large metal objects (e.g., boiler cases, mirrors) in the line of sight between the transmitter and receiver, as these will block the RF signal.

Wiring

DBR Receiver: Connect to terminals N, L, 1, 2, 3, 4. Terminals 3 and 4 are for COM and OUT connections. Ensure 230V AC, 50Hz power supply.

DBR Receiver wiring diagram
DBR Receiver wiring diagram

TPOne-S: Connect to terminals N and L for 230V AC power. If using the table stand, use only the provided power supply and USB cable.

Setup Wizard

The setup wizard launches automatically upon first power-up. Follow the on-screen prompts to configure:

  • Language
  • Date and Time
  • Hot Water Setup
  • RF Pairing (press OK to pair, then press the button on the receiver to confirm)

User Interface and Comfort Modes

The interface uses navigation buttons (Up, Down, Left, Right, OK, Back) and a Menu button. Comfort modes simplify daily scheduling:

TPOne-S User Interface
TPOne-S User Interface
  • Home: For occupied periods. Supports AM/PM temperature settings.
  • Away: For unoccupied periods.
  • Asleep: For nighttime temperature settings.
  • Standby: Switches heating off but maintains frost protection.

Settings and Configuration

Access the User Menu for daily schedules, temperature adjustments, and holiday settings. The Installer Settings menu (accessible by qualified personnel) allows for advanced configuration, including:

  • Hot Water Setup: Enable/disable domestic hot water control.
  • Control Type: Choose between On/Off or chrono-proportional (3, 6, or 12 cycle rate).
  • Start-up Method: Normal, Delayed Start (Economy), or Optimised Start (Comfort).
  • Service Interval: Set boiler service reminders with specific restriction modes (Warning Only to No Heating).

Troubleshooting and Warnings

The TPOne-S displays warning messages at the top of the screen. Common issues include:

  • RF Lost: Check for obstructions between the thermostat and receiver.
  • Pairing Failed: Perform manual pairing via the Installer Menu.
  • Frost Risk: Temperature dropped below 5°C; check heating system.
  • Sensor Fail: Internal sensor error; contact service provider.

Manufacturer information

Danfoss A/S

Brand profile

Practical help

Common problems

RF Lost warning

Ensure no large metal objects (boiler cases, mirrors) are obstructing the line of sight between the thermostat and receiver.

Pairing Failed

Ensure the connection is not obstructed. Use the Installer Menu to initiate manual pairing.

Low Heat warning

If the set temperature is not reached within 2 hours, check that the heating system is operating correctly.

Sensor Fail

If the internal temperature sensor is measuring outside operational parameters and cannot be reset, contact your service provider.

Before use

  • Ensure installation is performed by a qualified electrician or heating installer.
  • Verify the mounting location is 1.5m from the floor and away from draughts.
  • Confirm the receiver is at least 30cm away from metal enclosures.
  • Check that the power supply is 230V AC, 50Hz.
  • Ensure the TPOne-S App is downloaded if using WiFi features.

Specs in practice

Operating Voltage
230V AC, 50Hz power requirement.
Transmission frequency
868.42 MHz used for RF communication between thermostat and receiver.
WiFi Specification
802.11b/g (2.4GHz) for internet connectivity and remote control.

Images and diagrams

  • Wiring diagram for DBR Receiver shows terminals N, L, 1, 2, 3, 4.
  • Mounting diagram illustrates the 30cm minimum distance from metal objects and 1.5m height recommendation.

Model compatibility

  • Requires a separate hot water cylinder thermostat for domestic hot water control.
  • Compatible with modulating heaters.