This document provides instructions for the Einhell 18V Power X-Change battery, specifically regarding its capacity conversion feature, charge level monitoring, and troubleshooting. The battery is supplied in the 4.0 Ah (72 Wh) configuration but can be converted to 6.0 Ah (108 Wh) for longer runtime, or back to 4.0 Ah for extended total service life.

Battery capacity conversion

The battery can be converted between two modes using a 9-digit key sequence entered via the capacity indicator button (A).

Battery indicator buttons and display
Battery indicator buttons and display
  1. Hold the capacity indicator button (A) for approximately 6 seconds until the display (B) starts counting from 1 to 9. Release the button.
  2. To convert from 4.0 Ah to 6.0 Ah: Press button (A) briefly when the number 6 appears.
  3. To convert from 6.0 Ah to 4.0 Ah: Press button (A) briefly when the number 4 appears.
  4. After the display counts to 9, the new capacity (6Ah or 4Ah) will be shown for about 2 seconds.

Important: Conversion only occurs if the button is pressed precisely when the digit 4 or 6 appears. After conversion, the battery is treated as a different device with a new article number. New specification labels can be obtained at www.isc-gmbh.info.

Battery charge level indicator

Press the button (A) briefly. The display (B) will show the charge status in % for 2 seconds, followed by the currently set capacity for 2 seconds. Note that the charge level may need to be adjusted after conversion; it is recommended to charge the battery after changing the capacity setting.

Safety and transport

For transport according to special provision 188, the battery must be set to the 4.0 Ah (72 Wh) configuration. Defective batteries must not be sent normally; contact iSC GmbH at Eschenstrasse 6, 94405 Landau/Isar, Germany, or visit www.isc-gmbh.info.

Troubleshooting

The battery features an error code system on the display:

  • F01: Battery too hot (e.g., direct sunlight). Store at room temperature for one day.
  • F02: Battery too cold. Store at room temperature for one day.
  • F03: Battery overloaded. Remove from device and try again.
  • F04: Battery defective. Do not use.
  • F05: Battery partially deeply discharged. Recharge the battery.

Manufacturer information

Einhell

Brand profile

Practical help

Common problems

Battery is too hot or too cold (F01/F02)

Store the battery at room temperature (approx. 20°C) for one day.

Battery is overloaded (F03)

Remove the battery from the device and try again.

Battery is defective (F04)

Do not use the battery anymore.

Battery is partially deeply discharged (F05)

Recharge the battery.

Before use

  • Read all safety instructions carefully.
  • Check the current capacity setting using the indicator button.
  • Ensure the battery is charged before first use or after capacity conversion.
  • Verify the battery is set to 4.0 Ah if you intend to transport it under special provision 188.

Specs in practice

4.0 Ah / 72 Wh
Standard setting; provides gentler usage for the battery, resulting in approximately 3x longer total service life.
6.0 Ah / 108 Wh
High-capacity setting; provides longer runtime per battery charge.

Images and diagrams

  • A: Button for battery charge level indicator.
  • B: Display for battery charge level indicator.

Model compatibility

  • The battery is supplied in the 4.0 Ah configuration.
  • After conversion, the battery is considered a different device with a different article number.

Manual page author

Michael Turner

Technical manual editor

Reviews PDF manuals for structure, safety notes, and practical product details so readers can find the right information quickly.