This document provides essential instructions for the Einhell TE-VC 1925 SA wet and dry vacuum cleaner. Always ensure the correct filter is installed for the intended task (wet or dry). The device is not suitable for vacuuming hazardous dust or flammable substances.

Device description and items supplied

The vacuum cleaner includes a 25L tank, a flexible suction hose, a dual-purpose nozzle, a crevice nozzle, an upholstery nozzle, and an electric tool adapter. It features an automatic socket for power tools.

Assembly

Fitting the wheels: Insert the split pin through the axle hole, add a washer and wheel, slide the axle through the tank guides, and secure the second wheel with a washer and split pin. Snap the covers onto the wheels.

Fitting the castors: Push the castors into the mountings on the tank underside until they click into place.

Fitting the appliance head: Secure the head to the tank using the locking hooks, ensuring they click into place correctly.

Filter installation

Important: Never use the vacuum without a filter.

  • Dry vacuuming: Use the pleated filter.
  • Wet vacuuming: Use the foam filter.

Operation

Switch settings: 0 (Off), I (Normal operation), AUTO (Automatic mode for power tools). In AUTO mode, the vacuum starts automatically when the connected power tool is switched on.

Wet vacuuming: The safety float valve closes when the tank is full, causing the suction noise to increase. Switch off the device and empty the tank using the water drain screw.

Cleaning and maintenance

Clean the device regularly with a damp cloth and soft soap. Do not use solvents. Clean the pleated filter by tapping it or using a soft brush. Clean the foam filter with soap and water, then let it air dry.

Manufacturer information

Einhell

Brand profile

Practical help

Common problems

Suction noise becomes louder during wet vacuuming

The safety float valve has closed due to a full tank. Switch off the device and empty the tank.

Device does not start in automatic mode

Ensure the power tool is correctly connected to the automatic socket and the switch is set to AUTO.

Before use

  • Check that the mains voltage matches the rating plate.
  • Ensure the correct filter is installed (foam for wet, pleated for dry).
  • Verify all filters are securely fitted.
  • Ensure the tank is empty before starting.
  • Check that the power cable is in perfect condition.

Specs in practice

Container volume
25 liters total capacity.
Max. power consumption (total)
3400 W maximum combined load.

Model compatibility

  • Not suitable for vacuuming hazardous dust.
  • Not suitable for vacuuming flammable liquids or substances.