Quick answers from the manual

Quick answer

  • The Eurolamp 20L LED Panel Dehumidifier is a high-capacity unit designed to remove excess moisture from indoor air. It features four operation modes (Automatic, Continuous, Dry Clothes, Air Clean), a 5.5L water tank, and a timer function. p. 1, 4, 6

Key actions

  • Emptying the water tank p. 10
  • Cleaning the air filters p. 14

First start

  • Plug in the unit, ensure the water tank is correctly positioned, and press the power button to start. p. 10

Problems and fixes

No operation

Check power connection, empty water tank, or ensure tank is seated correctly.

p. 15

Maintenance and reset

  • Clean filters every 2 weeks; replace air clean filter every 6 months. p. 14

Technical specifications

Parameter Value Meaning Pages
Dehumidify Capacity 20L/day At 30°C, 80% RH p. 4
Rated Input Power 320W Power consumption p. 4

Where to find it in the PDF

  • Parts and Functions p. 5
  • Controls p. 6
Table of contents

Manual images

Click an image to enlarge

Quick Guide

The Eurolamp 20L LED Panel Dehumidifier is designed to remove excess humidity from indoor environments. It features a 5.5L water tank and multiple operation modes to suit different needs, such as drying clothes or cleaning the air. Always ensure the unit is placed on a flat, stable surface and that there is sufficient clearance around the device for proper airflow.

Safety Precautions

  • Electrical Safety: Ensure the voltage is 220-240V. Keep hands dry when handling the plug. Do not use damaged power cords.
  • Usage Restrictions: Do not use the unit outdoors, in places with chemicals, or near flammable gases. Do not use it as a chair or footstool.
  • Water Tank: Do not drink the collected water. Do not remove the float lever from the tank.
  • Maintenance: Always turn off and unplug the unit before cleaning or maintenance.

Parts and Functions

The unit consists of the following main components:

Parts and Functions diagram
Parts and Functions diagram
  • Front: Upward Air Outlet, Handle.
  • Back: Controls, Air Intakes, Water Tank.

Installation

For efficient operation, maintain the following minimum clearances:

Installation spacing requirements
Installation spacing requirements
  • Up: 30cm or more
  • Back: 20cm or more
  • Left: 20cm or more
  • Right: 20cm or more
  • Front: 10cm or more

Note: If TV sets or radios are disturbed by noise, keep them at least 70cm away from the dehumidifier.

Operation

To operate the unit, plug it into an outlet and press the power button. Use the MODE button to cycle through the following settings:

Control panel layout
Control panel layout
  • Automatic: Dehumidifies the room and stops when humidity is below approximately 55%.
  • Continuous: Ideal for closets or continuous operation.
  • Dry Clothes: High-performance mode for drying laundry.
  • Air Clean: Circulates air (not intended as an exclusive air cleaner).

You can also use the TIMER button to set a delayed power-off (0-24 hours).

Maintenance

Filter installation steps
Filter installation steps
Emptying the water tank
Emptying the water tank
  • Water Tank: When full, the unit stops automatically. Pull the tank out, empty it, and reinsert it gently.
  • Air Filters: Clean the back and side air intakes every 2 weeks. Remove the back cover, take out the filters, and vacuum or wash with neutral detergent. Let them dry completely before reinserting. The air clean filter should be replaced approximately every 6 months.
  • Cleaning the Unit: Wipe with a dry, soft cloth. Do not use gasoline, thinner, or liquid cleaners.

Troubleshooting

If the unit does not operate, check if the power plug is disconnected, the water tank is full, or the tank is not set properly. If the dehumidified volume is low, check if the filters are dirty or if air openings are blocked. If the unit makes a loud sound, ensure it is installed on a flat, stable floor.

Manufacturer information

EUROLAMP S.A.

Brand profile

Practical help

Common problems

No operation

Check if the power plug is disconnected, the water tank is full, or the tank is not set properly.

Dehumidified volume is small

Check if the filters are dirty, air openings are blocked, or the unit is in Air Clean mode.

Loud sound during operation

Ensure the unit is installed on a flat and stable floor.

Washed clothes are not dried

Ensure clothes are exposed to the airflow and the room temperature is not too low.

Before use

  • Ensure the unit is placed on a flat, stable surface.
  • Check that the water tank is inserted correctly.
  • Verify the power supply is 220-240V.
  • Ensure there is sufficient clearance (10-30cm) around the unit.
  • Check that the air filters are clean and properly installed.

Specs in practice

Dehumidify Capacity
20L/day (at 30°C, 80% RH) or 10L/day (at 27°C, 60% RH).
Rated Input Power
320W.
Water Tank Capacity
5.5L.
Airflow Volume
195m³/h.

Images and diagrams

  • Front view shows the upward air outlet and handle.
  • Back view shows the control panel, air intakes, and water tank location.
  • Installation diagram indicates required spacing from walls and furniture.

Model compatibility

  • Not suitable for keeping humidity below 50%.
  • Not intended for use as an exclusive air cleaner.
  • Do not use in rooms with kerosene heaters emitting vapor.

Manual page author