User Manual for Eurolamp 20L LED Panel Dehumidifier
Quick guide for the Eurolamp 20L LED Panel Dehumidifier. Learn how to operate, install, maintain, and troubleshoot your device effectively.
Quick answers from the manual
Quick answer
- The Eurolamp 20L LED Panel Dehumidifier is a high-capacity unit designed to remove excess moisture from indoor air. It features four operation modes (Automatic, Continuous, Dry Clothes, Air Clean), a 5.5L water tank, and a timer function. p. 1, 4, 6
Key actions
- Emptying the water tank p. 10
- Cleaning the air filters p. 14
First start
- Plug in the unit, ensure the water tank is correctly positioned, and press the power button to start. p. 10
Problems and fixes
Check power connection, empty water tank, or ensure tank is seated correctly.
p. 15Maintenance and reset
- Clean filters every 2 weeks; replace air clean filter every 6 months. p. 14
Technical specifications
| Parameter | Value | Meaning | Pages |
|---|---|---|---|
| Dehumidify Capacity | 20L/day | At 30°C, 80% RH | p. 4 |
| Rated Input Power | 320W | Power consumption | p. 4 |
Where to find it in the PDF
- Parts and Functions p. 5
- Controls p. 6
Table of contents
Manual images
Click an image to enlargeQuick Guide
The Eurolamp 20L LED Panel Dehumidifier is designed to remove excess humidity from indoor environments. It features a 5.5L water tank and multiple operation modes to suit different needs, such as drying clothes or cleaning the air. Always ensure the unit is placed on a flat, stable surface and that there is sufficient clearance around the device for proper airflow.
Safety Precautions
- Electrical Safety: Ensure the voltage is 220-240V. Keep hands dry when handling the plug. Do not use damaged power cords.
- Usage Restrictions: Do not use the unit outdoors, in places with chemicals, or near flammable gases. Do not use it as a chair or footstool.
- Water Tank: Do not drink the collected water. Do not remove the float lever from the tank.
- Maintenance: Always turn off and unplug the unit before cleaning or maintenance.
Parts and Functions
The unit consists of the following main components:

- Front: Upward Air Outlet, Handle.
- Back: Controls, Air Intakes, Water Tank.
Installation
For efficient operation, maintain the following minimum clearances:

- Up: 30cm or more
- Back: 20cm or more
- Left: 20cm or more
- Right: 20cm or more
- Front: 10cm or more
Note: If TV sets or radios are disturbed by noise, keep them at least 70cm away from the dehumidifier.
Operation
To operate the unit, plug it into an outlet and press the power button. Use the MODE button to cycle through the following settings:

- Automatic: Dehumidifies the room and stops when humidity is below approximately 55%.
- Continuous: Ideal for closets or continuous operation.
- Dry Clothes: High-performance mode for drying laundry.
- Air Clean: Circulates air (not intended as an exclusive air cleaner).
You can also use the TIMER button to set a delayed power-off (0-24 hours).
Maintenance


- Water Tank: When full, the unit stops automatically. Pull the tank out, empty it, and reinsert it gently.
- Air Filters: Clean the back and side air intakes every 2 weeks. Remove the back cover, take out the filters, and vacuum or wash with neutral detergent. Let them dry completely before reinserting. The air clean filter should be replaced approximately every 6 months.
- Cleaning the Unit: Wipe with a dry, soft cloth. Do not use gasoline, thinner, or liquid cleaners.
Troubleshooting
If the unit does not operate, check if the power plug is disconnected, the water tank is full, or the tank is not set properly. If the dehumidified volume is low, check if the filters are dirty or if air openings are blocked. If the unit makes a loud sound, ensure it is installed on a flat, stable floor.
Manufacturer information
EUROLAMP S.A.
Practical help
Common problems
Check if the power plug is disconnected, the water tank is full, or the tank is not set properly.
Check if the filters are dirty, air openings are blocked, or the unit is in Air Clean mode.
Ensure the unit is installed on a flat and stable floor.
Ensure clothes are exposed to the airflow and the room temperature is not too low.
Before use
- Ensure the unit is placed on a flat, stable surface.
- Check that the water tank is inserted correctly.
- Verify the power supply is 220-240V.
- Ensure there is sufficient clearance (10-30cm) around the unit.
- Check that the air filters are clean and properly installed.
Specs in practice
- Dehumidify Capacity
- 20L/day (at 30°C, 80% RH) or 10L/day (at 27°C, 60% RH).
- Rated Input Power
- 320W.
- Water Tank Capacity
- 5.5L.
- Airflow Volume
- 195m³/h.
Images and diagrams
- Front view shows the upward air outlet and handle.
- Back view shows the control panel, air intakes, and water tank location.
- Installation diagram indicates required spacing from walls and furniture.
Model compatibility
- Not suitable for keeping humidity below 50%.
- Not intended for use as an exclusive air cleaner.
- Do not use in rooms with kerosene heaters emitting vapor.
Manual page author
Emily Carter
User documentation editor
Prepares concise manual descriptions and highlights the most useful setup, operation, and maintenance information for readers.