Troubleshooting and Service Manual for Furrion 12" 2-Burner Gas Cooktop FGH12D2MA1B-BL

Quick guide for the Furrion 12" 2-Burner Gas Cooktop (FGH12D2MA1B-BL). Includes troubleshooting, maintenance, pressure check procedures, and a replaceable parts list.

Quick answers from the manual

Quick answer

  • This manual provides service and troubleshooting information for the Furrion 12" 2-Burner Gas Cooktop, including pressure testing, leak detection, and maintenance procedures. p. 1, 2

Key actions

  • Perform a pressure check p. 4
  • Perform a gas leak check p. 5

Problems and fixes

Surface burners do not ignite

Ensure gas supply valve is open, clean burner ports, or hold control knob in for 5 seconds after ignition.

p. 8
Show 2 more answers Show less

Technical specifications

Parameter Value Meaning Pages
Front Burner 8000 BTU Heat output p. 8
Rear Burner 6500 BTU Heat output p. 8
Inlet Pressure 10" WC - 13.8" WC Required gas pressure p. 8
Power input 12V DC <2 Amp Electrical requirement p. 8

Where to find it in the PDF

  • Pressure Check p. 4
  • Cleaning and Maintenance p. 5
  • Replaceable Parts List p. 6, 7
  • Troubleshooting p. 8
Table of contents

Manual images

Click an image to enlarge

Quick guide from the manual

This manual provides essential service and troubleshooting information for the Furrion 12" 2-Burner Gas Cooktop. It covers safety procedures, pressure testing, cleaning, and component replacement. If you smell gas: Do not try to light any appliance, do not touch electrical switches, clear the area of all occupants, turn off the gas supply, and contact your gas supplier or fire department immediately.

Pressure Check

To perform a pressure check on the appliance:

Pressure test port location
Pressure test port location
Pressure gauge connection
Pressure gauge connection
  1. Turn off the LP gas supply to the appliance.
  2. Remove the screw with the sealing gasket from the pressure test port.
  3. Slide the rubber tube from your pressure check measuring device over the gas pressure test port to create a seal.
  4. Turn on the LP gas.
  5. The pressure gauge should measure between 10" WC and 13.8" WC.
  6. Turn off the gas, remove the tube, and replace the screw with the gasket.
  7. Tighten the screw to 1.3 Nm to 1.7 Nm.
  8. Perform a gas leak check on the port screw after reassembly.

Gas Leak Check

Always perform a leak test before operation:

  • Ensure all control knobs are in the OFF position.
  • Apply a gas leak detection liquid (such as soapy water) to the connections.
  • Bubbles indicate a leak.
  • Tighten loose joints or replace faulty parts if a leak is detected.

Cleaning and Maintenance

Follow these guidelines to maintain your cooktop:

  • Ensure the appliance is cool before cleaning or disassembling.
  • Use care around burners to avoid damaging the igniter electrode.
  • Use only non-abrasive plastic scrubbing pads and warm soapy water.
  • Do NOT use: Bleach, rust removers, grit/acid-type cleaners, ammonia-based cleaners, wire brushes, or metallic items on burner ports.
  • Keep the area clear of combustible materials and flammable vapors.

Troubleshooting

Common issues and solutions:

  • Burners do not ignite: Ensure gas supply is open, clean clogged burner ports with a small-gauge wire, check gas level, or hold the control knob in for at least 5 seconds after the flame is lit.
  • Flame burns half way around: Dry the burner thoroughly or clean ports.
  • Flame is orange: Allow the burner to operate for a few minutes to clear dust. Note that coastal areas may have orange flames due to salt air.

Manufacturer information

Furrion

Brand profile

Practical help

Common problems

Surface burners do not ignite

Ensure gas supply is open, clean burner ports, check gas level, or hold the control knob in for 5 seconds after ignition.

Flame burns half way around

Dry the burner thoroughly or clean ports with a small-gauge wire.

Flame is orange

Allow the burner to operate for a few minutes to clear dust; salt air in coastal areas may cause this.

Before use

  • Ensure gas supply valve is open.
  • Perform a gas leak test using soapy water on connections.
  • Ensure the appliance is properly grounded if using an external electrical source.
  • Wear eye protection during service or maintenance.
  • Verify the gas pressure is between 10" WC and 13.8" WC.
Show more Show less

Specs in practice

Front Burner
8000 BTU heat output
Inlet Pressure
10" WC Min to 13.8" WC Max

Images and diagrams

  • Exploded view diagrams are provided for identifying replaceable parts like burner modules, control valves, and igniters.
  • Specific diagrams illustrate the pressure test port location and the connection of the pressure tester.

Model compatibility

  • Propane fuel only.
  • Appliance must be installed by a qualified technician in accordance with state and local laws.