Installation Manual for Knightsbridge GUSPIKER / GUSPIKES Spike Light

Comprehensive installation and maintenance guide for the Knightsbridge GUSPIKER and GUSPIKES outdoor spike lights. Includes wiring instructions, mounting procedures, safety warnings, and technical specifications.

Quick answers from the manual

Quick answer

  • The GUSPIKER/GUSPIKES is a 230V IP65 outdoor light. It requires a GU10 lamp (max 35W) and must be earthed (Class I). It is suitable for ground spike or wall mounting. p. 2, 4

Key actions

  • Isolate mains before installation or maintenance. p. 2
  • Connect wiring: Live (brown), Earth (green/yellow), Neutral (blue). p. 4

First start

  • Ensure the ground is suitable for the spike, or use the bracket for wall mounting. Insert a GU10 lamp (max 35W) and switch on. p. 2, 4
Show 3 more answers Show less

Maintenance and reset

  • Clean external surfaces with a damp cloth and mild detergent. Do not use high-pressure washers. p. 5

Technical specifications

Parameter Value Meaning Pages
Voltage 230V Operating voltage p. 6
IP Rating IP65 Ingress protection p. 2, 6
Lamp Type GU10 Compatible lamp base p. 4
Max Wattage 35W Maximum lamp power p. 4

Where to find it in the PDF

  • Installation Instructions p. 2, 3, 4
  • Safety and Maintenance p. 2, 5
Table of contents

Manual images

Click an image to enlarge

Quick Guide from the Manual

The Knightsbridge GUSPIKER and GUSPIKES are outdoor luminaires designed for spike or wall mounting. They are IP65 rated and require a GU10 lamp (max 35W). These units must be earthed (Class I) and are not suitable for installation in coastal or marine environments.

Safety Information

  • Installation: Must be installed in accordance with the latest edition of the IEE Wiring Regulations (BS7671) and current Building Regulations. If in doubt, consult a qualified electrician.
  • Power: Always isolate the mains supply before installation or maintenance.
  • Circuit Load: Ensure the total load on the circuit does not exceed the rating of the circuit cable, fuse, or circuit breaker.
  • Environment: This product is not suitable for installation in or near a coastal or marine environment.

Installation

Fig 2: Cable protection requirements
Fig 2: Cable protection requirements
Fig 3: Wall mounting bracket installation
Fig 3: Wall mounting bracket installation

Spike Mounting

  1. Choose a position where the ground is suitable to firmly hold the spike and luminaire.
  2. Ensure the ground is not liable to flooding.
  3. Check that the spike does not infringe with any underground pipes or cables.
  4. The body of the product should not rest directly on the ground.

Wall Mounting

  1. Use the bracket as a template to mark the location for fixing holes.
  2. Drill the holes, ensuring you do not infringe with any gas/water pipes or electrical cables.
  3. Fix the bracket to the surface using suitable fixings (not included).

Wiring

Connect the luminaire to the mains supply ensuring correct polarity:

  • Live: Brown
  • Earth: Green/Yellow
  • Neutral: Blue

The preinstalled cable is for above-ground use only. Cables routed within walls or below ground must be protected by suitable conduit or trunking.

Maintenance and Cleaning

  • Clean external surfaces with a damp cloth using a mild solution of detergent and warm water only.
  • Do not use aggressive cleaning products, solvents, or high-pressure washers.
  • The product is dimmable depending on the lamp type used.
  • Recycle the product in the correct manner when it reaches the end of its life.

Practical help

Common problems

Product unsuitable for location

Do not install in or near coastal or marine environments.

Cable damage risk

Cables routed underground or within walls must be protected by suitable conduit or trunking.

Before use

  • Ensure mains power is isolated before starting work
  • Verify the ground is suitable for spike stability
  • Check that the installation location is not prone to flooding
  • Confirm the circuit load capacity
  • Ensure a suitable GU10 lamp (max 35W) is available
Show more Show less

Specs in practice

GU10 (max 35W)
The maximum wattage allowed for the lamp to prevent overheating.

Images and diagrams

  • Fig 1: Correct spike installation method
  • Fig 2: Proper cable protection for underground/wall routing
  • Fig 3: Wall mounting bracket installation