The Sealey SDH50110V is a 50L industrial dehumidifier designed to remove excess moisture from the air. Before use, ensure the unit is placed on a level, stable surface and that the voltage matches your power supply. Important: After assembly, do not use the unit for 2 hours to allow the refrigerant to settle. Always switch the unit to the OFF position before disconnecting from the mains.

Product overview
Product overview

Assembly

Wheel Installation: Lay the machine body down. Fix the wheel axle to the body using the 4 provided screws. Attach a wheel to both ends of the axle. Return the unit to an upright position.

Wheel and handle assembly
Wheel and handle assembly

Handle Installation: Align the holes in the brackets with the holes in the bottom of the handle. It is recommended to fix the screws in the lower holes first, then flip the handle upwards and secure it with the screws in the upper holes.

Operation

Water Tank Usage: You can use the water tank in two ways:

Water tank and drainage setup
Water tank and drainage setup
Control panel layout
Control panel layout
  • Direct Use: When the tank is full, the machine automatically shuts down, enters standby, and the "Full Water" indicator lights up. Empty the tank to resume operation.
  • Continuous Drainage: Remove the water tank and mount the drain pipe. Ensure the drainage pipe is not set higher than the water tank.

Control Panel: Use the ON/OFF button to power the unit. The + and - buttons adjust humidity settings (RH10% to 95%) and timing (00 to 24 hours). The Timing button allows you to set cycle timers for powering on or off.

Humidity Control and Defrosting

The compressor shuts down when the room humidity is 3% lower than the set value and restarts when it is 3% higher. The unit features an automatic defrosting function that activates based on coil temperature and ambient conditions. If the unit is shut down, the fan will run for 10 seconds.

Troubleshooting

If the unit fails to turn on, check the power supply, fuse, and ensure the water tank is installed correctly. If the unit is noisy, ensure it is on a firm, flat surface. If water is leaking, check that the unit is level and the drain pipe is not obstructed. For error codes like E1 (coil sensor fault) or E2/E3 (humidity/temperature sensor fault), contact a professional or the manufacturer.

Specifications

  • Model: SDH50110V
  • Power: 600W (at 27°C/60% RH) to 800W (at 30°C/80% RH)
  • Airflow: 300m³/hr
  • Working Space: 50-120m³
  • Working Temperature: 5-35°C
  • Refrigerant: R290 (0.2kg)
  • IP Rating: IP22

Manufacturer information

Sealey Group

Brand profile

Practical help

Common problems

Fails to turn on

Check power supply, fuse, water tank installation, or if the unit is currently in a defrosting cycle.

Unfavourable dehumidifying effect

Remove obstructions from air inlet/outlet, close doors and windows, or ensure ambient temperature is not too low.

Heavy noise

Ensure the ground is firm and flat; resettle the dehumidifier.

Water leakage

Ensure the unit is on a level surface and the drain pipe/outlet is not obstructed.

Before use

  • Inspect power cables and plugs for wear or damage.
  • Ensure the voltage matches the power supply.
  • Place the unit on a level and stable surface.
  • Ensure the water tank is correctly installed.
  • Wait 2 hours after assembly before first use.

Specs in practice

IP Rating: IP22
Protected against solid objects over 12.5mm and vertically falling water drops.
Working Space: 50-120m³
The recommended room volume for effective dehumidification.
Refrigerant: R290
Environmentally friendly refrigerant used in the system.

Images and diagrams

  • Fig 1: Overview of air inlet, filter screen, and water tank panel.
  • Fig 2: Wheel and handle assembly instructions.
  • Fig 3: Water tank and continuous drainage pipe setup.

Model compatibility

  • Do not use at ambient temperatures below 5°C.
  • Do not use in environments with combustible/explosive gas, dust, or chemicals.
  • Not for use by children under 8 without supervision.