Abestorm Hurricane 125P Commercial Dehumidifier User Manual

Quick guide for the Abestorm Hurricane 125P commercial dehumidifier. Includes setup, LCD display operation, maintenance, troubleshooting, and safety instructions.

Table of contents

Manual images

Click an image to enlarge

Quick Guide from the Manual

The Abestorm Hurricane 125P is a commercial dehumidifier designed for moisture control. For optimal performance, ensure the unit is placed on a stable surface and operated with all windows and doors closed. The unit requires a 115V/60Hz circuit protected by a GFCI outlet. Always ensure the drain hose is uncoiled and not blocked before operation.

Parts Diagram
Parts Diagram

Safety Instructions

  • Do not adjust or alter the unit in any way.
  • Use only with a 115V/60Hz circuit protected by a GFCI outlet.
  • Do not use extension cords or plug adapters.
  • Always unplug the unit before removing the cover.
  • Inspect the power cord for damage before use.

LCD Display and Operation

The control panel features four buttons: Power, Purge, Menu, and Set. The main interface displays input/output temperature and humidity, job hours, and life hours. The unit includes a humidistat to monitor the space; when conditions are outside the setpoint, the compressor activates. The 'Purge' function allows for manual drainage of the pump reservoir.

Control Panel Interface
Control Panel Interface

Maintenance

  • Filter: Check the MERV-8 filter for dirt or obstructions. Clean by vacuuming or washing with warm water (no soap).
  • Coils: Clean annually using an approved self-rinsing, foaming coil cleaner.
  • Pump: Periodically remove the housing to clean the pump reservoir.
  • Storage: Turn off the unit, allow it to dry, clean the pump reservoir, wrap the power cord, and cover the filter mesh.

Troubleshooting

If the unit displays an error code, refer to the following:

  • E1: Humidity sensor or communication error.
  • E4: Problem with the pump.
  • E5: Refrigerant leak (contact installer).
  • LO: Room temperature is below 33.8°F.
  • HI: Room temperature is above 110°F.

Manufacturer information

Abestorm

Brand profile

Practical help

Common problems

Display is blank

Verify that both ends of the power cord are plugged in and reset the power.

No air flow

Clean the filter and ensure the air inlet or outlet is not blocked.

Error Code E1

Humidity sensor or communication error. Ensure the sensor wire is connected at both ends.

Error Code E4

Problem with pump. Verify the pump is properly installed and functioning; unplug for two minutes and restart.

Error Code LO / HI

Room temperature is out of range (below 33.8°F or above 110°F). Adjust room temperature.

Before use

  • Ensure the unit is on a stable surface.
  • Check the power cord for signs of damage.
  • Verify the filter is clean and unobstructed.
  • Ensure the drain hose is uncoiled and not blocked.
  • Connect to a 115V/60Hz GFCI outlet.

Images and diagrams

  • Control Panel: Features Power, Purge, Menu, and Set buttons for system navigation.
  • Parts: Includes foldable handle, wheels, air inlet/outlet, and MERV-8 filter.

Model compatibility

  • Use only with 115V/60Hz circuits.
  • Do not use extension cords or plug adapters.
  • Operating temperature range: 33.8°F to 110°F.