This document provides instructions for replacing the wind cup assembly on an AcuRite 3-in-1 sensor (model 06000RM). This procedure is necessary if you are experiencing no wind speed readings or lower than expected readings, provided the sensor is mounted correctly. Note that you must remove the sensor from its mounting location to perform this replacement.

What you need

  • AcuRite 3-in-1 sensor
  • Phillips head screwdriver

Safety and battery handling

To prevent erroneous readings during handling and transport, you must remove the batteries from the sensor:

  1. Press the release lever and pull off the lower housing of the sensor.
  2. Remove the battery compartment cover and take out the batteries.
  3. After the bearing is replaced, reinsert the batteries following the polarity (+/–) diagram inside the compartment.
  4. Replace the battery compartment cover and the lower housing.

Installation procedure

Removing the 4 long screws to separate the sensor housing.
Removing the 4 long screws to separate the sensor housing.
Removing the old wind cup assembly.
Removing the old wind cup assembly.
Aligning the new wind cup assembly.
Aligning the new wind cup assembly.
Reinstalling the 4 long screws.
Reinstalling the 4 long screws.
  1. Remove 4 screws: Remove the 4 long screws and separate the upper portion of the sensor from the lower portion.
  2. Remove and discard: Remove the old wind cup assembly and discard it.
  3. Install wind cup assembly: Align the screw holes on the new wind cup assembly with the 3-in-1 sensor.
  4. Reinstall 4 long screws: Secure the new assembly by reinstalling the 4 long screws. Installation is complete.

Manufacturer information

AcuRite

Brand profile

Practical help

Common problems

No wind speed readings or lower than expected readings.

The bearings of the wind cup assembly may be worn and require replacement.

Before use

  • Ensure you have a Phillips head screwdriver.
  • Remove the 3-in-1 sensor from its mounting location.
  • Remove batteries from the sensor before handling to avoid erroneous readings.

Images and diagrams

  • The manual provides a visual sequence showing the removal of the 4 long screws to separate the sensor housing.
  • Images illustrate the separation of the old assembly and the alignment of the new wind cup assembly.
  • A QR code is provided in the manual to view an instructional video.

Model compatibility

  • This replacement part is specifically for the AcuRite 3-in-1 sensor (model 06000RM).