User Manual for EcoFlow OCEAN EV Charger 11.5kW
Quick guide for the EcoFlow OCEAN EV Charger 11.5kW (EF-EVAC-11K5). Includes safety instructions, technical specifications, installation requirements, and regulatory compliance information.
Table of contents
Quick guide from the manual
The EcoFlow OCEAN EV Charger (11.5kW) is a high-power charging solution designed for professional installation. Important: This device must be installed by qualified professionals only. It requires a dedicated electric circuit with a maximum of 60 amperes branch circuit overcurrent protection. Before operation, ensure all cables, connectors, and ports are dry and securely connected. The device is rated NEMA Type 4, suitable for both indoor and outdoor use.
Safety Instructions
Adherence to safety protocols is mandatory to prevent electric shock, fire, or property damage.
- General Precautions: Do not use the product if the flexible power cord, EV cable, or enclosure is frayed, cracked, or damaged. Always disconnect the device from all power sources before making electrical connections or performing maintenance.
- Electrical Safety: Ensure the device is intact before connecting cables. Use dedicated insulated tools for high-voltage operations.
- Grounding: The product must be connected to a grounded, metal, permanent wiring system. The PE pole of the power cables must be grounded. Do not operate the device without a properly installed ground conductor.
- Personnel Requirements: Only qualified professionals are permitted to install, operate, and maintain the device. Personnel must receive thorough training and understand all safety precautions.
Technical Specifications
The following specifications apply to the EF-EVAC-11K5 model:
- Charge Power: 11.5 kW (Configurable)
- Rated Input/Output Voltage: 208/240 VAC (L1, L2, PE)
- Rated Input/Output Current: 48 A
- Connector Type: SAE J1772, 24.6 ft (7.5 m)
- Approved Grid Configurations: TN, TT
- Communication: Wi-Fi (2.4G), Bluetooth, CAN, RS485
- Environmental Requirements: Storage temperature -40°F to +158°F (-40°C to +70°C); Operating temperature -22°F to +122°F (-30°C to +50°C)
- Protection: Includes AC overvoltage/undervoltage protection, output overcurrent protection, overtemperature protection, leakage protection, surge protection, and ground fault protection.
Regulatory Compliance
This device complies with Part 15 of the FCC Rules and Industry Canada license-exempt RSS standards. Operation is subject to the condition that the device does not cause harmful interference and must accept any interference received. The equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.
Manufacturer information
EcoFlow
Practical help
Common problems
Ensure all cables, connectors, and ports are dry and securely connected. Verify the device is properly grounded.
Ensure the device is installed on a dedicated circuit with 60A maximum branch circuit overcurrent protection. Verify all electrical connections comply with local standards.
Do not use the product if the enclosure, connector, or cable is broken, cracked, or shows signs of damage. Contact EcoFlow or a certified partner for repairs.
Before use
- Ensure installation is performed by a qualified professional.
- Verify the circuit is provided with 60A maximum branch circuit overcurrent protection.
- Check that all cables, connectors, and ports are dry.
- Ensure the device is permanently connected to a protective ground.
- Confirm the installation area is clear of debris (cardboard, foam, wire ties).
- Verify that all warning labels and nameplates are visible after installation.
Specs in practice
- Charge Power
- 11.5 kW (Configurable) - The maximum power output for EV charging.
- Connector Type
- SAE J1772 - The standard connector type for the provided 7.5m cable.
- Environmental Category
- NEMA Type 4 - Indicates the enclosure is suitable for both indoor and outdoor use, providing protection against dust and water.
- Rated Current
- 48 A - The maximum rated input/output current for the device.
Model compatibility
- Requires a dedicated electric circuit.
- Approved Grid Configurations: TN, TT.
- Requires external overcurrent protection device (RCCB) according to local regulations.