Falmec Design Tab Range Hood User Manual

Quick guide for the Falmec Design Tab range hood, covering installation, operation, maintenance, and safety instructions.

Table of contents

Quick guide from the manual

This manual provides essential instructions for the installation, operation, and maintenance of the Falmec Design Tab range hood. It is intended for qualified personnel for installation and for the end-user for daily operation and maintenance.

Falmec Design Tab range hood
Falmec Design Tab range hood

Safety

  • Installation must be performed by qualified personnel in compliance with local regulations.
  • Do not use the hood if the power cable or components are damaged.
  • Do not modify the electrical, mechanical, or functional structure of the unit.
  • Ensure proper earthing of the electrical system.
  • Do not connect the hood to combustion exhaust ducts (boilers, fireplaces, etc.).
  • Always disconnect the power supply before cleaning or maintenance.
  • Do not leave unattended flames under the hood.
  • Supervise deep-fryers during use as overheated oil can catch fire.

Installation

The hood can be installed in various configurations. Follow the specific steps provided in the manual for your chosen setup. Ensure the wall is suitable for the weight of the hood (Tab 60: 18 kg, Tab 80: 26 kg). Use the provided mounting kit only on masonry walls; for other materials, use appropriate alternative fastening systems.

Operation

The hood features an electronic control panel:

  • Motor ON/OFF: Turns the motor on and off.
  • Speed Increase: Increases speed from 1 to 4. Speed 4 is active for a few minutes, then reverts to speed 3.
  • Speed Decrease: Decreases speed from 4 to 1.
  • Light: Turns the light on and off.
  • Timer: Auto-switch-off after 15 minutes.
  • Filter Alarm: Indicates maintenance is needed after approximately 30 hours of use. Press the timer button for 3 seconds to reset.

Maintenance

  • Cleaning: Clean external surfaces at least every 15 days using non-abrasive detergents. Do not use excessive water near the control panel.
  • Metal Filters: Wash at least once a month in hot water with dish soap or in a dishwasher at low temperatures (max 60°C) without detergent.
  • Active Carbon Filters: Replace according to the instructions provided with the filters.

Technical Support

If the control panel is unresponsive, temporarily disconnect the power supply (approx. 5 seconds) to reset the system. If the issue persists, contact your dealer or an authorized service center.

Falmec S.p.A, via dell’Artigianato, 42 z.i., 31029 Vittorio Veneto, Treviso — Italy, [email protected], falmec.com

Manufacturer information

Falmec S.p.a.

Brand profile

Practical help

Common problems

Control panel is completely inactive.

Temporarily disconnect the power supply to the appliance (approx. 5 seconds), preferably via the main switch, to restore normal operation.

Filter alarm is active.

Perform maintenance on the anti-grease filters and press the timer button for 3 seconds to reset the counter.

Before use

  • Check that the electrical system is earthed and compliant with local standards.
  • Verify that the mains voltage matches the data plate inside the hood.
  • Ensure the hood is not installed outdoors or exposed to atmospheric elements.
  • Check that the metal anti-grease filters are correctly installed.
  • Ensure the room has adequate ventilation if other gas-powered appliances are in use.

Specs in practice

Filter cleaning interval
Every 30 hours of operation

Images and diagrams

  • The manual includes detailed diagrams for vertical and rear outlet installation.
  • Specific diagrams show the motor repositioning process for different configurations.
  • Diagrams illustrate the installation of the check valve and suction pipe.
  • Figures show the correct procedure for replacing LED spotlights.

Model compatibility

  • The provided mounting kit is for masonry walls only.
  • For gas cookers, the minimum distance is generally 65 cm, but may be reduced based on EN60335-2-31.
  • Check valves must be removed for internal recirculation (filtering) versions.

Manual page author

Emily Carter

User documentation editor

Prepares concise manual descriptions and highlights the most useful setup, operation, and maintenance information for readers.