findmanualpdf.com

User Manual for Fieldmann FVC 2011-EK and FVC 2013-EK Submersible Pump

Quick guide for Fieldmann FVC 2011-EK and FVC 2013-EK submersible pumps. Includes installation steps, maintenance tips, technical specifications, and troubleshooting.

Quick answers from the manual

Quick answer

  • The Fieldmann FVC 2011-EK and FVC 2013-EK are submersible pumps for private household use. They are designed for transferring water (e.g., garden, home) but are not suitable for sewage, salt water, or drinking water. Always ensure the pump is not run dry. p. 3, 6

Key actions

  • Regular maintenance p. 7

First start

  • Check tank dimensions and float switch p. 5

Problems and fixes

The pump does not start

Check the power supply and move the float to a higher position.

p. 8

Maintenance and reset

  • Rinse with clean water p. 7

Technical specifications

Parameter Value Meaning Pages
Power input 250 W / 400 W Power consumption for FVC 2011-EK / FVC 2013-EK p. 8

Where to find it in the PDF

  • Machine description p. 4
  • Technical specifications p. 8
Table of contents

Quick guide from the manual

This manual provides instructions for the Fieldmann FVC 2011-EK and FVC 2013-EK submersible pumps. These devices are designed for private household use to transfer water between locations. Important: Never run the pump dry, as this can damage the mechanical gasket. Ensure the pump is used in a tank with minimum dimensions of 40 x 40 x 50 cm to allow the float switch to move freely.

Machine description

The pump consists of the following main components:

Diagram of the submersible pump and its components.
Diagram of the submersible pump and its components.
  • Pump body
  • Power cord with electrical plug
  • Hose connection (with option to connect to 1"/2" hose)
  • Pump tube bend
  • Switching float (with height setting)

Installation

The pump can be installed in a permanent position using either a rigid or flexible pipe. Follow these guidelines:

  • Never hang the pump by the outlet hose or power cord without additional support.
  • The pump must be placed on the bottom of the tank or hung on a holder.
  • Ensure the bottom of the tank is protected against dirt and residue.
  • Check that the electrical connection is 230 V ~ 50 Hz and the socket is in good condition.
  • Ensure moisture cannot reach the electrical power source.

Operation

The pump is suitable for water in distribution systems and chlorinated pool water. It is not suitable for sewage, salt water, aggressive/combustible substances, food processing, or drinking water. The maximum water temperature is 35 °C.

Maintenance

To ensure a long lifetime, perform regular maintenance:

  • If the pump is moved frequently, rinse it with clean water after each use.
  • Check the working order of the switching float every 3 months.
  • Remove fibrous deposits inside the pump using a current of water.
  • Clean mud from the floor of the pumping pit every 3 months.
  • Remove deposits on the float using clean water.
  • If the impeller is clogged, flush the pump body with clean water.

Troubleshooting

If the pump does not start, check the power supply and ensure the float switch is not stuck. If the pump is not flowing, check if the suction sieve is clogged or the pressure hose is bent. If the pump turns off after a short time, it may be due to the temperature fuse; disconnect the plug, clean the pump, and ensure the water temperature does not exceed 35 °C.

Technical specifications

The FVC 2011-EK has a power input of 250 W and a maximum flow of 5000 l/h. The FVC 2013-EK has a power input of 400 W and a maximum flow of 7500 l/h. Both models operate at 230 V ~ 50 Hz and have a maximum media temperature of 35 °C.

Manufacturer information

Fieldmann

Brand profile

Practical help

Common problems

Pump does not start

Check the power supply and ensure the float switch is not stuck or positioned too low.

Not flowing

Check if the suction sieve is clogged or if the pressure hose is bent.

Pump turns off after a short time

The temperature fuse may have triggered due to dirty water or water temperature exceeding 35 °C. Disconnect, clean the pump, and check water temperature.

Before use

  • Ensure the tank dimensions are at least 40 x 40 x 50 cm.
  • Check that the power supply is 230 V ~ 50 Hz.
  • Verify the float switch moves freely and is not touching the underlay.
  • Ensure the outlet hose is attached correctly.
  • Check that the pump is standing on the bottom of the tank.

Specs in practice

Maximum temperature of the media
The pump must not be used in water exceeding 35 °C.
Maximum value of solid particles
FVC 2011-EK: 5 mm; FVC 2013-EK: 35 mm. Do not exceed these sizes to avoid clogging.

Images and diagrams

  • 2: Power cord
  • 3: Hose connection
  • 6: Switching float
  • 7: Height setting for the switching float

Model compatibility

  • Not suitable for sewage, salt water, or drinking water.
  • Not for professional use.

Manual page author

Emily Carter

User documentation editor

Prepares concise manual descriptions and highlights the most useful setup, operation, and maintenance information for readers.