Vanguard 125V 15 Amp Connector

Quick guide for the Vanguard 125V 15 Amp Connector. Includes wiring instructions, stripping dimensions, torque specifications, and safety warnings for proper installation.

Table of contents

Quick guide from the manual

This document provides instructions for the safe installation and wiring of the Vanguard 125V 15 Amp Connector. Before starting, ensure the power is disconnected. The device must be installed by a qualified person. Use only 16 AWG, 3-wire round jacket copper cord. Always wear ANSI-approved safety goggles during installation.

Specifications

  • Rating: 125VAC / 15A
  • Wire Capacity: 16 AWG, 3-wire, round jacket
  • NEMA Configuration: 5-15R / 5-15P
  • Compatible Cord Types: SJT, ST, S, SE, SJ, SJE groups

Wiring Instructions

Follow these steps to prepare and wire the connector:

Figure A: Wire stripping dimensions
Figure A: Wire stripping dimensions
  1. Preparation: Strip the cord jacket by 1 inch and the individual conductors by 3/8 inch. Twist the strands (do not tin the conductors).
  2. Opening: Separate the connector body and shell. Note that the plug/connector is keyed to the shell.
  3. Wiring Method: Slip the outer shell onto the cord first. Insert conductors into the identified terminal pockets:
    • Green wire: Connect to the green terminal pocket.
    • White wire: Connect to the white terminal pocket.
    • Black wire: Connect to the brass terminal pocket.
  4. Torque Requirements: Tighten terminal screws to 20 inch lb.

Assembly

  1. Align the key on the body with the key in the shell and slip the shell into the front section.
  2. Evenly tighten the assembly screws to 14 inch lb.
  3. Evenly tighten the cord grip screws to 14 inch lb.

Safety Information

To prevent serious injury or electric shock, observe the following:

  • Disconnect power before connecting.
  • Inspect the product before connecting and before every use; do not use if parts are loose or damaged.
  • Use the product only as intended.
  • Do not expose the connector to moisture or rain.
  • Keep the connector off the ground.
  • Tighten all connections securely.

Manufacturer information

Harbor Freight Tools

Brand profile

Practical help

Common problems

Wire does not fit or clamp properly

Ensure you are using 16 AWG round cord. Adjustment of cord clamps may be necessary depending on the specific cord size.

Unsure of wire connection points

Connect the Green wire to the green terminal, the White wire to the white terminal, and the Black wire to the brass terminal.

Before use

  • Disconnect power before connecting.
  • Wear ANSI-approved safety goggles.
  • Use only 16 AWG, 3-wire round jacket copper cord.
  • Ensure conductors are not tinned.
  • Verify the connector is not damaged or loose.

Images and diagrams

  • Figure A illustrates the required stripping lengths: 1 inch for the outer jacket and 3/8 inch for the individual conductors.

Model compatibility

  • Compatible with SJT, ST, S, SE, SJ, and SJE group cords.
  • Use copper wire only.