findmanualpdf.com

User manual for De'Longhi Tasciugo Ariadry Slim DES 16EW dehumidifier

Quick guide for the De'Longhi Tasciugo Ariadry Slim DES 16EW dehumidifier. Learn about installation, operating modes, filter maintenance, and troubleshooting.

Table of contents

Manual images

Click an image to enlarge

Quick guide from the manual

This dehumidifier is designed to remove excess humidity from the air. Before using the device, ensure it has been standing upright for at least 1 hour after transport. Maintain a minimum clearance of 50 cm in front of the unit to ensure proper air outlet. The device is intended for indoor domestic use only.

Description and accessories

The unit features a control panel, water level indicator, removable condensate tank, and a lifting handle. It includes an air intake grille, a silver ion air filter, an air outlet grille, a 2m condensate drainage hose, and casters for mobility.

Unit components and accessories
Unit components and accessories

Safety instructions

  • Do not touch the appliance or plug with wet hands.
  • Always unplug the device by gripping the plug, not the cord.
  • Do not use extension cords.
  • Ensure the device is properly grounded.
  • Do not use the appliance in laundry rooms or outdoors.
  • Keep the device away from heat sources and flammable substances.
  • Do not obstruct air intake or outlet grilles.

Installation

Position the unit in the room to be dehumidified. Ensure at least 50 cm of space in front and 5-10 cm behind the unit.

Continuous drainage installation
Continuous drainage installation
Caster installation
Caster installation

Condensate drainage

Tank drainage: Condensate is collected directly in the removable tank.

Continuous drainage: For long-term operation, unscrew the continuous drainage cap, remove the rubber stopper, and attach the provided rubber hose. Ensure the hose does not rise higher than the outlet nozzle and is not kinked.

Caster installation

To install the casters, unplug the unit and empty the tank. Remove the rubber stoppers from the base (use pliers if necessary) and insert the casters into the holes.

Operating modes

Dehumidification Mode: Allows setting the desired humidity level (30% to 80%) and fan speed (MIN/MAX). The unit stops when the target humidity is reached.

Control panel
Control panel

Dry Mode: Operates at maximum power for rapid dehumidification. Humidity and fan speed cannot be adjusted.

Smart Mode: Automatically selects optimal settings based on ambient conditions.

Ventilation Mode: Operates as a fan only. Fan speed can be adjusted.

Cleaning and maintenance

Always unplug the unit before cleaning. Clean the exterior with a damp cloth; do not use solvents or insecticides. The silver ion air filter should be cleaned regularly (weekly if used constantly). Extract the filter laterally, vacuum dust, or rinse with lukewarm water (max 40°C). Let it dry completely before reinserting.

Filter removal
Filter removal

Troubleshooting

If the unit does not dehumidify, check if the filter is clogged, the room is too large, or the humidity setting is too high. If the unit does not start, wait 3 minutes for the safety device to reset. If the display shows error codes, check the tank position or ambient temperature.

Technical specifications

  • Operating temperature: 2°C - 32°C
  • Operating humidity: 30% - 90%
  • Tank capacity: 3 litres
  • Fan speeds: 2
  • Dimensions: 485x375x190 mm

Practical help

Common problems

Unit does not dehumidify

Check if the filter is clogged, the room is too large, or the humidity setting is too high.

Unit does not start after being turned on

Wait 3 minutes for the internal safety device to reset.

Display shows error code (tank symbol)

Ensure the tank is present, empty, and correctly positioned.

Display shows error code (star symbol)

The room temperature is too low; increase the ambient temperature.

Before use

  • Wait at least 1 hour after transport before switching on.
  • Ensure the power outlet is grounded and accessible.
  • Check that the air intake and outlet are not obstructed.
  • Ensure the tank is correctly inserted.
  • Verify the room temperature is between 2°C and 32°C.

Specs in practice

Tank capacity
3 litres; requires emptying when full.
Operating temperature
2°C to 32°C; unit may not function efficiently outside this range.

Images and diagrams

  • The control panel allows selection of modes (Dehumidification, Dry, Smart, Ventilation) and adjustment of humidity levels.
  • Continuous drainage requires removing the rubber stopper and attaching the hose, ensuring it does not slope upwards.

Model compatibility

  • Not suitable for outdoor use.
  • Not suitable for use in laundry rooms.

Manual page author

Michael Turner

Technical manual editor

Reviews PDF manuals for structure, safety notes, and practical product details so readers can find the right information quickly.