User Guide for Sanela SLU 01N Automatic Faucet
Comprehensive user guide for the Sanela SLU 01N automatic washbasin tap. Includes installation instructions, electrical wiring diagrams, parameter configuration, and maintenance requirements.
Table of contents
Quick guide from the manual
The Sanela SLU 01N is an automatic washbasin tap designed for cold or premixed water. Crucial: The unit must be connected to a constant 24V DC power supply. Do not connect the power supply behind a light switch, as this will disrupt the sensor's operation and calibration.
Installation
Before installation, ensure you have read the safety instructions. The installation requires a 35 mm hole in the washbasin.
- Ensure the main water supply is turned off.
- Mount the faucet onto the washbasin.
- Connect the water supply hoses.
- Flush the water lines to remove debris before final connection.
- Connect the solenoid valve and sensor cables according to the wiring diagram.
- Ensure the water flow direction on the solenoid valve matches the arrow on the housing.
- Connect the 24V DC power supply, ensuring correct polarity (brown = positive, white = negative).
Operation and Settings
The faucet operates automatically via an infrared sensor. The default settings include an automatic stop after 5 minutes of continuous flow. Advanced settings, such as sensor range, flush duration, and hygienic flush intervals, can be configured using the SLD 03 remote control.
Parameter Settings
- Sensor Range: Adjustable between 0.1 and 0.3 m.
- Flush Duration: Adjustable between 0.25 and 7.75 seconds.
- Hygienic Flush: Can be set to intervals of 6, 8, 12, 24, 48, 72, or 168 hours, with a duration of 5 to 1200 seconds.
Maintenance
Regular maintenance is required to ensure proper functionality. Check the water supply sieve regularly; it must have a mesh size of ≤ 90 µm. If the flow decreases, clean the sieve and the aerator.
Technical Specifications
- Power Supply: 24V DC (constant voltage required).
- Operating Pressure: 0.1 - 0.6 MPa.
- Connection: G 1/2".
- Automatic Stop: 5 minutes.
Manufacturer information
SANELA spol. s r. o.
Practical help
Common problems
Verify that the power supply is connected to a constant 24V DC source and not switched via a light circuit.
Check the water supply sieve for debris (must be ≤ 90 µm) and ensure water pressure is within 0.1 - 0.6 MPa.
Use the SLD 03 remote control to adjust the sensor range between 0.1 and 0.3 m.
Before use
- Ensure a constant 24V DC power supply is available.
- Verify water pressure is between 0.1 and 0.6 MPa.
- Check that the mounting hole is 35 mm.
- Ensure the power supply is NOT connected to a light switch.
- Confirm the water supply sieve is clean and installed.
Specs in practice
- Sieve dimension ≤ 90 µm
- Maximum particle size allowed in the water supply to prevent valve clogging.
Model compatibility
- Compatible with SLZ series power supplies (SLZ 01Y, 01Z, 04Y, 04Z, 06).
- Compatible with SLT thermostatic mixing valves (SLT 04, 05).
- Requires SLD 03 remote control for advanced configuration.