Tecnolite 09YDLED430MV Recessed LED Downlight

Quick guide for installing and maintaining the Tecnolite 09YDLED430MV series recessed LED downlight. Includes mounting steps, electrical connection, and safety precautions.

Table of contents

Quick guide from the manual

This document provides installation and safety instructions for the Tecnolite 09YDLED430MV series recessed LED downlight. The fixture requires a 130mm diameter cutout and a minimum of 25cm of ventilation space to operate safely. Always disconnect the power supply before performing any installation or maintenance work.

Installation

Follow these steps to install the downlight:

Cutout and ventilation requirements
Cutout and ventilation requirements
  1. Prepare the ceiling: Cut a hole in the ceiling with a diameter of 130mm. Ensure there is at least 25cm of free space around the fixture for proper ventilation.
  2. Electrical connection: Connect the fixture to the power supply. Ensure the Line and Neutral wires are correctly connected according to the electrical diagram provided.
  3. Mounting: Insert the fixture into the ceiling cutout. Use the spring clips to secure the light in place, ensuring it sits flush against the ceiling surface.

Safety and maintenance

To ensure safe operation and longevity of the product, adhere to the following guidelines:

  • Safety: Keep the fixture at least 0.50 meters away from any combustible materials to avoid fire hazards.
  • Power: Always disconnect the power source before installation or maintenance.
  • Cleaning: Clean the luminaire and its internal parts with a dry rag. Periodically check all electrical connections to ensure they remain secure.
  • Usage: Do not use the fixture with voltages outside the range specified on the product label.

Technical specifications

  • Input Voltage: 100 V - 240 V, 50 Hz/60 Hz
  • Power: 9 W
  • Cutout Diameter: 130 mm
  • Minimum Ventilation: 25 cm

Manufacturer information

Tecnolite

Brand profile

Practical help

Common problems

Fixture overheating

Ensure there is at least 25cm of ventilation space around the fixture as specified in the installation requirements.

Fire hazard risk

Maintain a minimum distance of 0.50 meters from any combustible materials.

Before use

  • Verify the ceiling cutout diameter is exactly 130mm.
  • Ensure the power supply is disconnected before starting installation.
  • Check that the installation area is free of combustible materials.
  • Confirm the input voltage is within the 100V-240V range.
  • Ensure you have the necessary tools for electrical connection.

Images and diagrams

  • Step 1 illustrates the 130mm cutout requirement and the 25cm ventilation clearance.
  • Step 2 shows the electrical wiring diagram for Line and Neutral connections.
  • Step 3 demonstrates the spring clip mechanism for securing the light into the ceiling.

Model compatibility

  • The fixture is designed for indoor use only.
  • Compatible with LED technology.
  • The use of microwave sensors is recommended for optimal performance.